Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AZAR INTERNATIONAL INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AZAR INTERNATIONAL INC. in 31 W. PROSPECT STREET, NANUET, NY 10954 (NAICS 321219). OSHA activity number 339158032.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Azar International INC. — free Get an email when a new federal OSHA severe-injury report for Azar International INC. is published. One employer, no account, unsubscribe in one click.
Site address
31 W. PROSPECT STREET
City
NANUET
State
NY
ZIP
10954
Mailing
31 W. PROSPECT STREET, NANUET, NY 10954
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321219
Employees
20
Ownership type
A

9 citations on file for this inspection.

1910.24 H

Serious Gravity 5 1 instance 10 exposed
Issued
Nov 18, 2013
Abate by
Dec 20, 2013
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.24(h): Standard railings were not provided on the open sides of all exposed stairways and stair platforms:    On or about 7/8/13    Location: 31 West Prospect Street, Nanuet, NY 10954    a) A five step wooden stairway in the main production area did not have standard railings on either open side.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.178 G02

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 18, 2013
Abate by
Dec 20, 2013
Penalty
Initial $1,200 · Current $600 Reduced
29 CFR 1910.178(g)(2): Battery charging apparatus for industrial trucks located in battery changing and charging installation was not protected from damage by trucks:     On or about 7/8/13     Location: 31 West Prospect Street, Nanuet, NY 10954     a) The Deka battery charger for the for the Hyster forklift truck was located on the ground and not protected from damage from the forks/truck.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1910.212 A05

Serious Gravity 1 1 instance 4 exposed
Issued
Nov 18, 2013
Abate by
Dec 20, 2013
Penalty
Initial $1,200 · Current $600 Reduced
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch:     On or about 7/8/13     Location: 31 West Prospect Street, Nanuet, NY 10954     a) The guard on the Diehl pedestal mounted floor fan had openings that were greater than one half inch.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1910.213 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 18, 2013
Abate by
Dec 20, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:     On or about 7/8/13     Location: Cut Room, 31 West Prospect Street, Nanuet, NY 10954     a) Two Delta unisaw table saws did not have automatically adjusting guards above the saw blade.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.219 D01

Serious Gravity 5 3 instances 6 exposed
Issued
Nov 18, 2013
Abate by
Dec 20, 2013
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    On or about 7/8/13    Location: 31 West Prospect Street, Nanuet, NY 10954    a) The motor and compressor drive pulleys on the Succss horizontal air compressor were not guarded.    b) The motor and compressor drive pulleys on the Binks spray system compressor were not guarded.    c) The drive pulley on the Rockwell Delta ram type radial drill was not guarded.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.219 E01 I

Serious Gravity 5 3 instances 6 exposed
Issued
Nov 18, 2013
Abate by
Dec 20, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o):  On or about 7/8/13  Location 31 West Prospect Street, Nanuet, NY 10954  a) The triple "V" drive belts on the Success horizontal compressor were not guarded.  b) The single "V" drive belt on the Binks spray system compressor was not guarded.  c) The drive belt on the Rockwell Delta ram type radial drill was not guarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 3 instances 8 exposed
Issued
Nov 18, 2013
Abate by
Dec 20, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:     On or about 7/8/13     Location: 31 West Prospect Street, Nanuet, NY 10954     a) Three metal "J" boxes, listed only to be used attached to a surface as part of the permanent building wiring, were used as a 120 volt electrical distribution points at the end of electrical cords.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.303 F

Serious Gravity 1 1 instance 8 exposed
Issued
Nov 18, 2013
Abate by
Dec 20, 2013
Penalty
Initial $1,200 · Current $600 Reduced
29 CFR 1910.303(f): Each service, feeder and branch circuit, at its disconnecting means or over current device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:     On or about 7/8/13    Location 31 West Prospect Street, Nanuet, NY 10954    a) The individual breakers in the circuit breaker panels in a 120 volt panel in the production area were not labeled or marked to indicate their purpose.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1910.305 G01 IV A

Serious Gravity 5 3 instances 10 exposed
Issued
Nov 18, 2013
Abate by
Dec 20, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:     On or about 7/8/13    Location: 31 West Prospect Street, Nanuet, NY 10954     a) Orange extension cords were used in place of permanent building wiring to provide power to fans and other equipment in fixed locations. The cords were run over and attached to electrical conduit, piping and building structural members.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

View Azar International INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339158032.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.