OSHA Inspection: FRANCISCAN VILLA OF SOUTH MILWAUKEE, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of FRANCISCAN VILLA OF SOUTH MILWAUKEE, INC. in 3601 S. CHICAGO AVE., SOUTH MILWAUKEE, WI 53172 (NAICS 623110). OSHA activity number 339167207.

Watch Franciscan Villa OF South Milwaukee, INC. — free Get an email when a new federal OSHA severe-injury report for Franciscan Villa OF South Milwaukee, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3601 S. CHICAGO AVE.
City
SOUTH MILWAUKEE
State
WI
ZIP
53172
Mailing
3601 S. CHICAGO AVE., SOUTH MILWAUKEE, WI 53172
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
623110
Employees
245
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 30, 2013
Abate by
Oct 24, 2013
Penalty
Initial $3,600 · Current $2,160 Reduced
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):    a)  The energy control program did not include specific procedures that provided the rules and protocol to follow for the placement of lockout devices, shutting down to secure all energy sources, testing  and removal of devices when procedure is complete.  Equipment serviced includes but is not limited to air handlers, compressors, dishwasher, stoves and tub lifts.
Recent events (2)
  • — I (S) $2160
  • — Z (S) $3600

1910.303 G01 II

Other-than-serious 1 instance 5 exposed
Issued
Sep 30, 2013
Penalty
Initial $2,700 · Current $1,000 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electrical equipment rated 600 volts, nominal, or less to ground, was in a passageway or general open space and was not suitably guarded when normally enclosed live parts were exposed for inspection or servicing:     a)  The electrical panels located in the maintenance storage room  area was obstructed by walkers, beds and other stored equipment.
Recent events (2)
  • — I (O) $1000
  • — Z (S) $2700

1910.305 B01 II

Other-than-serious 1 instance 2 exposed
Issued
Sep 30, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  a)  The electrical cabinet located on the first floor serving area was missing a knockout plug, exposing employees to a potential contact with the energized live wiring enclosed.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Franciscan Villa OF South Milwaukee, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339167207.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.