COLUMBUS, OH —
OSHA Inspection: SEATON CORP., DBA STAFF MANAGEMENT
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of SEATON CORP., DBA STAFF MANAGEMENT in 5115 FISHER ROAD, COLUMBUS, OH 43228 (NAICS 561320). OSHA activity number 339167231.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SEATON CORP., DBA STAFF MANAGEMENT
- Site address
- 5115 FISHER ROAD
- City
- COLUMBUS
- State
- OH
- ZIP
- 43228
- Mailing
- 860 W. EVERGREEN, CHICAGO, IL 60642
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561320
- Employees
- 247
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.23 A09
- Issued
- Oct 25, 2013
- Abate by
- Nov 29, 2013
- Penalty
- Initial $4,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.23(a)(9): Every floor hole into which persons cannot accidentally walk (on account of fixed machinery, equipment, or walls) shall be protected by a cover that leaves no openings more than 1 inch wide. The cover shall be securely held in place to prevent tools or materials from falling through. a. On the Line 6 Flexible Filling platform, there was an unguarded floor hole beside the flexible filing conveyor Number 1 through 4 which measured 19 inches x 28 inches thereby exposing employees to a trip fall hazard.
Recent events (3)
- — D (S) $0
- — C (S) $4000
- — Z (S) $4000
1910.147 C07 I
- Issued
- Oct 25, 2013
- Abate by
- Jun 18, 2015
- Penalty
- Initial $5,000 · Current $5,000
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following: a. The employer did not ensure that its training of employees to perform cleaning of machines was fully documented regarding the procedures to properly lock out a machine.
Recent events (3)
- — F (O) $5000
- — C (S) $5000
- — Z (S) $5000
1910.304 G05
- Issued
- Oct 25, 2013
- Abate by
- Nov 14, 2013
- Penalty
- Initial $3,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective. a. In the 2% inspection area, the industrial fan did not have a ground prong on the electrical power cord thereby exposing employees to a contact hazard. b. On the Line 6 flexible filling unloader platform, the industrial fan electrical power cord used to cool employees did not have a ground prong thereby exposing employees to a contact hazard.
Recent events (3)
- — D (S) $0
- — C (S) $3000
- — Z (S) $3000
1910.334 A02 I
- Issued
- Oct 25, 2013
- Abate by
- Nov 13, 2013
- Penalty
- Initial $3,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) shall be visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket). Cord and plug connected equipment and flexible cord sets (extension cords) which remain connected once they are put in place and are not exposed to damage need not be visually inspected until they are relocated. a. In the 2% inspection area, the industrial fan did not have a ground prong on the electrical power cord thereby exposing employees to a contact hazard. b. On the Line 6 flexible filling unloader platform, the industrial fan electrical power cord used to cool employees did not have a ground prong thereby exposing employees to a contact hazard.
Recent events (3)
- — D (S) $0
- — C (S) $3000
- — Z (S) $3000
1910.132 D01
- Issued
- Oct 25, 2013
- Abate by
- Nov 29, 2013
- Penalty
- Initial $200 · Current $0 Reduced
General-duty citation text
29 CFR 1910.132(d)(1): The employer shall assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). If such hazards are present, or likely to be present, the employer shall: 29 CFR 1910.132(d)(1)(i): Select, and have each affected employee use, the types of PPE that will protect the affected employee from the hazards identified in the hazard assessment; a. In the Mars Plant, the employer did not identify and develop a hazard assessment for employees working in the plant to protect employees from potential and anticipated hazards during work performed in the plant. The Seaton Corporation dba Staff Management was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.132(d)(1), which was contained in OSHA inspection number 312732134, citation number 1, item number 2, and was affirmed as a final order on August 26, 2009, with respect to a workplace located at 1 Blachley Road, Stamford, CT, 06922.
Recent events (3)
- — D (R) $0
- — C (R) $200
- — Z (R) $200
1910.132 D02
- Issued
- Oct 25, 2013
- Abate by
- Jun 18, 2015
- Penalty
- Initial $0 · Current $200
General-duty citation text
29 CFR 1910.132(d)(2): The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment. a. On the site, the employer did not verify that the workplace hazard assessment was performed and a written certification documented to indicte the assessment was completed.
Recent events (3)
- — F (O) $200
- — C (O) $0
- — Z (O) $0
More inspections at Seaton Corp., DBA Staff Management
View Seaton Corp., DBA Staff Management's full OSHA safety record →
More inspections in this industry (NAICS 561320)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339167231.