SARASOTA, FL ·
OSHA Inspection: TRIDENT BUILDING SYSTEMS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TRIDENT BUILDING SYSTEMS, INC. in 2812 TALLEVAST RD, SARASOTA, FL 34243 (NAICS 332311). OSHA activity number 339175069.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TRIDENT BUILDING SYSTEMS, INC.
- Site address
- 2812 TALLEVAST RD
- City
- SARASOTA
- State
- FL
- ZIP
- 34243
- Mailing
- 2812 TALLEVAST RD, SARASOTA, FL 34243
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332311
- Employees
- 92
- Ownership type
- Private (A)
Citations
9 citations on file for this inspection.
1910.147 C04 I
- Issued
- Nov 4, 2013
- Abate by
- Dec 23, 2013
- Penalty
- Initial $1,890 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) At the forming department, PBR (Purllin Bearing Roof), Roller machine used to fabricate wall and roof panels did not have lock out/tag out procedures when maintenance employees did maintenance and repairs, on or about July 31, 2013.
Recent events (3)
- · R (S) $0
- · C (S) $1890
- · Z (S) $1890
1910.157 G02
- Issued
- Nov 4, 2013
- Abate by
- Dec 23, 2013
- Penalty
- Initial $1,890 · Current $1,417 Reduced
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: (a) At the establishment, employees were not trained annually on the principles of fire extinguishers use, on or about July 31, 2013.
Recent events (3)
- · R (O) $1417
- · C (S) $1890
- · Z (S) $1890
1910.215 A04
- Issued
- Nov 4, 2013
- Abate by
- Dec 23, 2013
- Penalty
- Initial $3,150 · Current $3,150
General-duty citation text
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work: (a)At the maintenance shop, a Delta 8" bench grinder, Model 23-880, was not equipped with a work rest, on or about July 30, 2013.
Recent events (3)
- · R (S) $3150
- · C (S) $3150
- · Z (S) $3150
1910.215 B09
- Issued
- Nov 4, 2013
- Penalty
- Initial $3,150 · Current $0 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: (a) At the maintenance shop, the tongue guard of a Delta 8" bench grinder, Model 23-880, exceed one forth inch. The tongue guard measured 1" from the wheel, on or about July 30, 2013.
Recent events (3)
- · R (S) $0
- · C (S) $3150
- · Z (S) $3150
1910.253 B04 III
- Issued
- Nov 4, 2013
- Abate by
- Dec 23, 2013
- Penalty
- Initial $3,150 · Current $3,150
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: (a) At the compressed storage area, oxygen tanks were stored beside acetylene tanks, on or about July 30, 2013.
Recent events (3)
- · R (S) $3150
- · C (S) $3150
- · Z (S) $3150
1910.23 D01 IV
- Issued
- Nov 4, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(d)(1)(iv): The employer did not ensure that stairs with four or more risers that were more than 44 inches wide but less than 88 inches wide had a stair railing on each open side and a handrail on each enclosed side. a) At the loading dock, the stair leading to the parking lot, had four risers and 45 inches wide, without intermediate rail, on or about July 31, 2013.
Recent events (3)
- · R (O) $0
- · C (O) $0
- · Z (O) $0
1910.38 F
- Issued
- Nov 4, 2013
- Abate by
- Dec 23, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.38(f): 29 CFR 1910.38(f): The employer did not review the emergency action plan with each employee covered by the plan in accordance with 1910.38(f)(1) through (f)(3). a) At the establishment, employees were not aware where to meet in case of emergency evacuation, or on about July 31, 2013.
Recent events (3)
- · R (O) $0
- · C (O) $0
- · Z (O) $0
1910.39 C
- Issued
- Nov 4, 2013
- Abate by
- Dec 23, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.39(c): A fire prevention plan did not include the minimum elements: a) At the establishment, the fire prevention plan did not include the following elements, on or about July 31, 2013: 1. A list of all major fire hazards, proper handling and storage procedures for hazardous materials, potential ignition sources and their control, and the type of fire protection equipment necessary to control each major hazard; 2. Procedures to control accumulations of flammable and combustible waste materials; 3. Procedures for regular maintenance of safeguards installed on heat-producing equipment to prevent the accidental ignition of combustible materials; 4. The name or job title of employees responsible for maintaining equipment to prevent or control sources of ignition or fires; and 5. The name or job title of employees responsible for the control of fuel source hazards.
Recent events (3)
- · R (O) $0
- · C (O) $0
- · Z (O) $0
1910.147 C06 I
- Issued
- Nov 4, 2013
- Abate by
- Dec 23, 2013
- Penalty
- Initial $630 · Current $630
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) At the production area, machines such as but not limited to Geica, on or about July 30, 2013.
Recent events (3)
- · R (O) $630
- · C (O) $630
- · Z (O) $630
More inspections at Trident Building Systems, INC.
View Trident Building Systems, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332311)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339175069.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.