METUCHEN, NJ ·
OSHA Inspection: DIVINE PRINTING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DIVINE PRINTING, INC. in 131 LIBERTY ST., METUCHEN, NJ 08840 (NAICS 323112). OSHA activity number 339179749.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DIVINE PRINTING, INC.
- Site address
- 131 LIBERTY ST.
- City
- METUCHEN
- State
- NJ
- ZIP
- 08840
- Mailing
- 131 LIBERTY ST., METUCHEN, NJ 08840
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323112
- Employees
- 20
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.22 B01
- Issued
- Aug 8, 2013
- Abate by
- Aug 27, 2013
- Penalty
- Initial $2,380 · Current $1,548 Reduced
General-duty citation text
29 CFR 1910.22(b)(1): Aisle(s) or passageways(s) were not kept clear mechanical handling equipment were used. a/ Divine Printing/Metuchen NJ Site Production Sorting/Packaging/Shredding Areas: 1/ Where employees are required to work in compartments or work stations, the aisles leading to and from the work areas were blocked by rolls of paper product, pallets stocked with product, cardboard boxes, shredded product, etrc. 2/ Aisles at the wall side of the operations (mentioned above were not maintained free of rolls of paper product and electrical cable. Observed on/or about 7/11/2013
Recent events (3)
- · R (S) $1548
- · C (S) $2380
- · Z (S) $2380
1910.37 A03
- Issued
- Aug 8, 2013
- Abate by
- Aug 27, 2013
- Penalty
- Initial $1,785 · Current $862 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit routes were not continuously maintained free of obstructions or impediments to full instant use in the case of fire or other emergency: a/ Divine Printing/Metuchen NJ Site Yard/Production Side of Bldg.: Exit access-way had vegetaton that was not removed and/or cut to a height where employees could freely travel to a safe place from the building in the event of a fire or other emergency. Observed on/or about 7/11/2013
Recent events (3)
- · R (S) $862
- · C (S) $1785
- · Z (S) $1785
1910.147 C04 II
- Issued
- Aug 8, 2013
- Abate by
- Sep 4, 2013
- Penalty
- Initial $2,975 · Current $1,934 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D)(h): a/ Divine Printing/Metuchen NJ Site Plant Area:: Operators who are required to perform service and/or limited maintenance on printing machinery and/or other machinery are not provided with specific guidelines and information on lockout/tagout equipment to ensure proper procedures are followed. 1/ Procedures are to be tailored to each piece or a group of similar equipment, including but not limited to Mark Andy Printing Presses #1, #2 and #4; and all hard wired and/or large machines/equipment where maintenance operator does not have exclusive control over the cord-plug connection. 2/ Training must be provided when procedures are developed. Observed on/or about 7/11/2013.
Recent events (3)
- · R (S) $1934
- · C (S) $2975
- · Z (S) $2975
1910.178 L04 III
- Issued
- Aug 8, 2013
- Abate by
- Sep 4, 2013
- Penalty
- Initial $2,380 · Current $0 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): The employer did not ensure that an evaluation of each powered industrial truck operator's performance was conducted at least once every three years: a/ Divine Printing/Metuchen NJ Site Plant/Warehouse: Industrial truck operator(s) were not provided an evaluation of training in excess of the last 3 years. Observed on/or about 7/11/2013.
Recent events (3)
- · R (S) $0
- · C (S) $2380
- · Z (S) $2380
1910.212 A01
- Issued
- Aug 8, 2013
- Abate by
- Sep 4, 2013
- Penalty
- Initial $2,975 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by crushing action of horizontal ram: a/ Divine Printing/Metuchen NJ Site Warehouse Dock Area: Industrial Compactor (no markings) had no guard and/or other approved means to prevent employee contact with moving ram during compacting operation. Observed on/or about 7/11/2013.
Recent events (3)
- · R (S) $0
- · C (S) $2975
- · Z (S) $2975
1910.219 C02 I
- Issued
- Aug 8, 2013
- Abate by
- Sep 4, 2013
- Penalty
- Initial $2,975 · Current $1,934 Reduced
General-duty citation text
29 CFR 1910.219(c)(2)(i): Exposed part(s) of horizontal shafting were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: a/ Divine Printing/Metuchen NJ Site Production Printing Area: "Mark Andy" Printing presses, (including but not limited to) Press #1, #2 and #4 had rotating shafts that had no guards and/or other approved means to prevent employee contact during monitoring and/or servicing operations. Observed on/or about 7/11/2013.
Recent events (3)
- · R (S) $1934
- · C (S) $2975
- · Z (S) $2975
1910.303 G01 II
- Issued
- Aug 8, 2013
- Abate by
- Aug 27, 2013
- Penalty
- Initial $1,785 · Current $862 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(ii): Working space provided about electrical equipment rated 600 volts, nominal, or less was used for storage: a/ Divine Printing/Metuchen NJ Site Production Sorting/Packaging/Shredding Areas: Electrical breaker and panel boxes were blocked by rolls of paper product, a trash can and a wooden pallet. Electrical boxes rated 480 volts 3/phase were not maintained free of storage. A minimum 30 inches of working space was not provided. Observed on/or about 7/11/2013.
Recent events (3)
- · R (S) $862
- · C (S) $1785
- · Z (S) $1785
1910.110 B06 VI
- Issued
- Aug 8, 2013
- Abate by
- Aug 27, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.110(b)(6)(vi): Readily ignitable material was not removed within 10 feet of LP gas container(s): a/ Divine Printing/Metuchen NJ Site Yard/Production Side of Bldg.: Propane gas tanks stored in an eight capacity metal cage were not maintained free of weeds and grass. Observed on/or about 7/11/2013.
Recent events (3)
- · R (O) $0
- · C (O) $0
- · Z (O) $0
1910.179 B05
- Issued
- Aug 8, 2013
- Abate by
- Aug 27, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(b)(5): Rated load marking on crane(s) were not clearly legible from the ground or the floor: a/ Divine Printing/Metuchen NJ Site Production/Slitting Area: Dayton Pendant Type Crane/Hoist - The weight capacity was not visible from the floor area. Observed on/or about 7/11/2013
Recent events (3)
- · R (O) $0
- · C (O) $0
- · Z (O) $0
More inspections at Divine Printing, INC.
View Divine Printing, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 323112)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339179749.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.