OSHA Inspection: VALMONT NEWMARK

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of VALMONT NEWMARK in 101 CARLETON AVE., HAZLETON, PA 18201 (NAICS 332999). OSHA activity number 339180838.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Valmont Newmark — free Get an email when a new federal OSHA severe-injury report for Valmont Newmark is published. One employer, no account, unsubscribe in one click.
Establishment
VALMONT NEWMARK
Site address
101 CARLETON AVE.
City
HAZLETON
State
PA
ZIP
18201
Mailing
101 CARLETON AVE., HAZLETON, PA 18201
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
84
Ownership type
A

1 citation on file for this inspection.

1910.146 C06

Other-than-serious 1 instance 18 exposed
Issued
Sep 30, 2013
Abate by
Nov 2, 2013
Penalty
Initial $4,000 · Current $2,000 Reduced

Hazardous substances 0240

29 CFR 1910.146(c)(6): When there were changes in the use or configuration of a non-permit confined space that could increase the hazards to entrants, the employer did not reevaluate that space and, when necessary, reclassify it as a permit-required confined space:    (a) Tube welding operations, the installation of sealer plates and end baffles changed the interior of the tube non-permit required confined spaces such that natural ventilation and egress were impeded.   The written confined space policy and working procedures did not address the use and specific placement of air venturi ventilators and the periodic removal of wire welding leads to lessen the potential for accidental buildup of shielding gas in the spaces.  The policy did not address the potential for trapezoidal and other end plates to so restrict the egress that employees would have to us their hands or contort their bodies to enter into or exit from the confined space, on or about, July 31, 2013.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (O) $2000
  • — Z (S) $4000

View Valmont Newmark's full OSHA safety record →