OSHA Inspection: SUSCON, INCORPORATED

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SUSCON, INCORPORATED in 600 RAILWAY ST, WILLIAMSPORT, PA 17701 (NAICS 326160). OSHA activity number 339182651.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Suscon, Incorporated — free Get an email when a new federal OSHA severe-injury report for Suscon, Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
600 RAILWAY ST
City
WILLIAMSPORT
State
PA
ZIP
17701
Mailing
600 RAILWAY ST, WILLIAMSPORT, PA 17701
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326160
Employees
55
Ownership type
A

8 citations on file for this inspection.

1910.147 D04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 31, 2013
Abate by
Sep 17, 2013
Penalty
Initial $2,625 · Current $1,969 Reduced
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  a) Production area: Maintenance was being performed on the #5 Uniloy blow mold machine and a lockout or tagout device was not affixed to the energy isolating device, as observed on or about July 11, 2013.  Abatement Certification Required.
Recent events (2)
  • — I (S) $1968.75
  • — Z (S) $2625

1910.147 C04 II

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 31, 2013
Abate by
Sep 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):  Maintenance: Energy control procedures for equipment including, but not limited to, blow mold machines, grinders and compactors did not clearly and specifically outline the scope, purpose, authorization, rules and techniques to be utilized for the control of hazardous energy, on or about July 11, 2013.  Abatement Certification Required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 31, 2013
Abate by
Sep 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed:  a) Maintenance: The employer did not conduct a periodic inspection of the energy control procedures at least annually, on or about July 11, 2013.  Abatement Certification Required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 3 instances 2 exposed
Issued
Jul 31, 2013
Abate by
Sep 17, 2013
Penalty
Initial $1,575 · Current $1,181 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a) Production area: Electrical handy boxes (2) were being used as part of extension cord assemblies and were not securely mounted, as observed on or about July 11, 2013.  b) Maintenance storage room: An electrical handy box was being used as part of an extension cord assembly and was not securely mounted, as observed on or about July 11, 2013.  Abatement Certification Required.
Recent events (2)
  • — I (S) $1181.25
  • — Z (S) $1575

1910.303 G02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 31, 2013
Abate by
Sep 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  a) Production area: The door of the control cabinet on the Bekum 3 blow mold machine was open exposing the electrical conductors to contact, as observed on or about July 11, 2013.  Abatement Certification Required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B04 III

Serious Gravity 1 1 instance 2 exposed
Issued
Jul 31, 2013
Abate by
Sep 17, 2013
Penalty
Initial $1,575 · Current $1,181 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one half hour:  a) Compressor area: Oxygen (4) and acetylene (2) cylinders were being stored next to each other without a noncombustible barrier, as observed on or about July 11, 2013.  Abatement Certification Required.
Recent events (2)
  • — I (S) $1181.25
  • — Z (S) $1575

1910.178 L01 I

Other-than-serious 1 instance 2 exposed
Issued
Jul 31, 2013
Abate by
Sep 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  a) Maintenance: Maintenance employees, operating powered industrial trucks (forklifts), had not completed the training and evaluation specified in this paragraph (i), on or about July 12, 2013.  Abatement Certification Required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.212 A01

Other-than-serious 1 instance 1 exposed
Issued
Jul 31, 2013
Abate by
Sep 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  Production area: A guard at the rear of the Bekum 3 blow mold machine was missing, as observed on or about July 11, 2013.  Abatement Certification Required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Suscon, Incorporated's full OSHA safety record →