WILLIAMSPORT, PA —
OSHA Inspection: SUSCON, INCORPORATED
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SUSCON, INCORPORATED in 600 RAILWAY ST, WILLIAMSPORT, PA 17701 (NAICS 326160). OSHA activity number 339182651.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SUSCON, INCORPORATED
- Site address
- 600 RAILWAY ST
- City
- WILLIAMSPORT
- State
- PA
- ZIP
- 17701
- Mailing
- 600 RAILWAY ST, WILLIAMSPORT, PA 17701
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326160
- Employees
- 55
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.147 D04 I
- Issued
- Jul 31, 2013
- Abate by
- Sep 17, 2013
- Penalty
- Initial $2,625 · Current $1,969 Reduced
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) Production area: Maintenance was being performed on the #5 Uniloy blow mold machine and a lockout or tagout device was not affixed to the energy isolating device, as observed on or about July 11, 2013. Abatement Certification Required.
Recent events (2)
- — I (S) $1968.75
- — Z (S) $2625
1910.147 C04 II
- Issued
- Jul 31, 2013
- Abate by
- Sep 17, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): Maintenance: Energy control procedures for equipment including, but not limited to, blow mold machines, grinders and compactors did not clearly and specifically outline the scope, purpose, authorization, rules and techniques to be utilized for the control of hazardous energy, on or about July 11, 2013. Abatement Certification Required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- Jul 31, 2013
- Abate by
- Sep 17, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: a) Maintenance: The employer did not conduct a periodic inspection of the energy control procedures at least annually, on or about July 11, 2013. Abatement Certification Required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B02
- Issued
- Jul 31, 2013
- Abate by
- Sep 17, 2013
- Penalty
- Initial $1,575 · Current $1,181 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Production area: Electrical handy boxes (2) were being used as part of extension cord assemblies and were not securely mounted, as observed on or about July 11, 2013. b) Maintenance storage room: An electrical handy box was being used as part of an extension cord assembly and was not securely mounted, as observed on or about July 11, 2013. Abatement Certification Required.
Recent events (2)
- — I (S) $1181.25
- — Z (S) $1575
1910.303 G02 I
- Issued
- Jul 31, 2013
- Abate by
- Sep 17, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a) Production area: The door of the control cabinet on the Bekum 3 blow mold machine was open exposing the electrical conductors to contact, as observed on or about July 11, 2013. Abatement Certification Required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.253 B04 III
- Issued
- Jul 31, 2013
- Abate by
- Sep 17, 2013
- Penalty
- Initial $1,575 · Current $1,181 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one half hour: a) Compressor area: Oxygen (4) and acetylene (2) cylinders were being stored next to each other without a noncombustible barrier, as observed on or about July 11, 2013. Abatement Certification Required.
Recent events (2)
- — I (S) $1181.25
- — Z (S) $1575
1910.178 L01 I
- Issued
- Jul 31, 2013
- Abate by
- Sep 17, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) Maintenance: Maintenance employees, operating powered industrial trucks (forklifts), had not completed the training and evaluation specified in this paragraph (i), on or about July 12, 2013. Abatement Certification Required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.212 A01
- Issued
- Jul 31, 2013
- Abate by
- Sep 17, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Production area: A guard at the rear of the Bekum 3 blow mold machine was missing, as observed on or about July 11, 2013. Abatement Certification Required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Suscon, Incorporated
View Suscon, Incorporated's full OSHA safety record →
More inspections in this industry (NAICS 326160)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339182651.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.