Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: GRAND IRON WORK INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GRAND IRON WORK INC. in 5239 W. GRAND AVE., CHICAGO, IL 60639 (NAICS 331111). OSHA activity number 339194011.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Grand Iron Work INC. for free Get an email when a new federal OSHA severe-injury report for Grand Iron Work INC. is published. One employer, no account, unsubscribe in one click.
Site address
5239 W. GRAND AVE.
City
CHICAGO
State
IL
ZIP
60639
Mailing
5239 W. GRAND AVE., CHICAGO, IL 60639
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331111
Employees
12
Ownership type
A

7 citations on file for this inspection.

1910.36 D01

Serious Gravity 1 1 instance 5 exposed
Issued
Aug 5, 2013
Abate by
Aug 29, 2013
Penalty
Initial $1,200 · Current $1,200
29 CFR 1910.36(d)(1): Employees were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:   Shop Area, South End - The exit door was locked from the inside.  The exit door had a bar across it and locked with a padlock preventing employees from exiting the building during an emergency.
Recent events (1)
  • · Z (S) $1200

1910.212 A03 II

Serious Gravity 10 1 instance 4 exposed
Issued
Aug 5, 2013
Abate by
Aug 29, 2013
Penalty
Initial $2,800 · Current $2,800
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  Shop Area - The point of operation was not guarded on the Presshear serial #R10456, using a foot pedal control.
Recent events (1)
  • · Z (S) $2800

1910.243 C01

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 5, 2013
Abate by
Aug 29, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1910.243(c)(1): Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4):  a) Shop Area - A portable grinder was used without a safety guard.
Recent events (1)
  • · Z (S) $2000

1910.253 B02 II

Serious Gravity 5 1 instance 5 exposed
Issued
Aug 5, 2013
Abate by
Aug 29, 2013
Penalty
Initial $1,600 · Current $1,600
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, and gangways, or where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons:       a) Shop Area - Acetylene cylinder was not secured from physical damage by passing or falling objects.
Recent events (1)
  • · Z (S) $1600

1910.303 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 5, 2013
Abate by
Aug 29, 2013
Penalty
Initial $1,600 · Current $1,600
29 CFR 1910.303(b)(2): Listed or labeled equipment were not used or installed in accordance with any instructions included in the listing or labeling:    a) Shop Area - The metal duplex receptacle outlet was not installed in accordance with the listing or labeling while being used to provide electricity to a fan and other equipment.
Recent events (1)
  • · Z (S) $1600

1910.305 B01 II

Other-than-serious 2 instances 4 exposed
Issued
Aug 5, 2013
Abate by
Aug 29, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings were not effectively closed:     a) Shop Area Near Welding Area on Conduit - A metal junction box had four knockouts missing.   b) Shop Against North Wall - Two outlet receptacle had a knockout missing.
Recent events (1)
  • · Z (O) $0

1910.334 A02 I

Other-than-serious 2 instances 5 exposed
Issued
Aug 5, 2013
Abate by
Aug 29, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):        a) Shop Area - An orange electrical extension cord powering a light that had its outer sheath damaged.  b) Shop Area - A yellow electrical extension cord powering a battery charger that had its outer sheath damaged.  c) Shop Area - There was a circular fan with an electrical cord that had the protective sheath detached from the end.
Recent events (1)
  • · Z (O) $0

View Grand Iron Work INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339194011.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.