OSHA Inspection: GRAND IRON WORK INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GRAND IRON WORK INC. in 1385 BROWN ST., DES PLAINES, IL 60016 (NAICS 238120). OSHA activity number 342520145.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Grand Iron Work INC. for free Get an email when a new federal OSHA severe-injury report for Grand Iron Work INC. is published. One employer, no account, unsubscribe in one click.
Site address
1385 BROWN ST.
City
DES PLAINES
State
IL
ZIP
60016
Mailing
5239 W. GRAND AVE., CHICAGO, IL 60639
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
5
Ownership type
A

5 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 1 exposed
Issued
Feb 8, 2018
Abate by
Mar 14, 2018
Penalty
Initial $311 · Current $311
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:   Grand Iron Work Inc., failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected:   Citation Number            Item Number                    Abatement Date  01                                01                                   11/07/2017  01                                02                                   11/07/2017  02                                01                                   11/07/2017  02                                02                                   11/07/2017  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF THE CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • · Z (O) $311

1926.351 B04

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 1, 2017
Abate by
Nov 7, 2017
Penalty
Initial $4,183 · Current $4,183
29 CFR 1926.351(b)(4): Welding cable(s) in use were in need of repair:  a) On August 3, 2017, employees were provided with and used welding cables with worn insulation as evidenced by the exposed un-insulated conductors.
Recent events (1)
  • · Z (S) $4183

1926.760 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 1, 2017
Abate by
Nov 7, 2017
Penalty
Initial $4,183 · Current $4,183
29 CFR 1926.760(a)(1): Each employee engaged in steel erection activity who was on a walking/working surface with an unprotected side or edge more than 15 feet (4.6m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems or personal fall restraint systems:  a) On August 3, 2017, employees working on the structural steel frame work of the building were not protected from falling approximately 31 feet.
Recent events (1)
  • · Z (S) $4183

1926.404 F06

Other-than-serious 1 instance 2 exposed
Issued
Nov 1, 2017
Abate by
Nov 7, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:  a) On August 3, 2017, the employer provided for employee use at the job site an extension cord that did not have a grounding pin.
Recent events (1)
  • · Z (O) $0

1926.416 E01

Other-than-serious 1 instance 2 exposed
Issued
Nov 1, 2017
Abate by
Nov 7, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:  a) On August 3, 2017, the insulation on the flexible cord being used by employees to provide power to the top floor of the building was worn as evidenced by the exposed insulated conductors.
Recent events (1)