Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: CLEMENS ENTERPRISES, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CLEMENS ENTERPRISES, INC. in 4026 MONROEVILLE BOULEVARD, MONROEVILLE, PA 15146 (NAICS 812320). OSHA activity number 339196016.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Clemens Enterprises, INC. for free Get an email when a new federal OSHA severe-injury report for Clemens Enterprises, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4026 MONROEVILLE BOULEVARD
City
MONROEVILLE
State
PA
ZIP
15146
Mailing
4026 MONROEVILLE BOULEVARD, MONROEVILLE, PA 15146
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
812320
Employees
15
Ownership type
A

3 citations on file for this inspection.

1910.147 C01

Serious Gravity 1 1 instance 15 exposed
Issued
Jul 29, 2013
Abate by
Sep 13, 2013
Penalty
Initial $1,200 · Current $774 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:     (a) Facility, 4026 Monroeville Boulevard, Monroeville, PA:  On or about 07/16/13 the employer did not establish an energy control program that included control procedures, employee training and periodic inspections.  Employees perform maintenance on equipment without utilizing energy controls and are exposed to energy sources such as, but not limited to: electrical, water and steam.
Recent events (2)
  • · I (S) $774
  • · Z (S) $1200

1910.303 G02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 29, 2013
Abate by
Aug 8, 2013
Penalty
Initial $2,000 · Current $1,290 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):     (a) Facility, 4026 Monroeville Boulevard, Monroeville, PA:  On or about 07/16/13 the control button on the Wascoclean Donini dry cleaner did not function and employees open the cabinet and use a metal tool to depress the on/off switch.  The switch, operating at 220 volts, has the copper connections uncovered exposing employees to potential electrical shock hazards when performing this operation.
Recent events (2)
  • · I (S) $1290
  • · Z (S) $2000

1910.305 B02

Other-than-serious 3 instances 3 exposed
Issued
Jul 29, 2013
Abate by
Aug 8, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:   (a) Facility, 4026 Monroeville Boulevard, Monroeville, PA:  On or about 07/16/13 no cover was in place on the junction box located at the Wascoclean Donini dry cleaner.   (b) Facility, 4026 Monroeville Boulevard, Monroeville, PA:  On or about 07/16/13 no cover was in place on the junction box located the 2nd Pants Ajax press.   (c) Facility, 4026 Monroeville Boulevard, Monroeville, PA:  On or about 07/16/13 no cover was in place on the junction box located near the steam valve for the drape press.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Clemens Enterprises, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339196016.