Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CRJ BUILDER CORP.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CRJ BUILDER CORP. in 52-09 MARATHON PARKWAY, LITTLE NECK, NY 11362 (NAICS 238130). OSHA activity number 339203127.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CRJ Builder Corp. — free Get an email when a new federal OSHA severe-injury report for CRJ Builder Corp. is published. One employer, no account, unsubscribe in one click.
Establishment
CRJ BUILDER CORP.
Site address
52-09 MARATHON PARKWAY
City
LITTLE NECK
State
NY
ZIP
11362
Mailing
50-47 175TH STREET, FRESH MEADOWS, NY 11365
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
A

8 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 30, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:     a) On or about January 15, 2013- at the site of 52-09 Marathon Parkway Little Neck, NY 11362.    Employees exposed to overhead hazards from framers up to 12-feet above next lower level.       ABATEMENT VERIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.102 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 30, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:  a) On or about January 15, 2013- at the site of 52-09 Marathon Parkway Little Neck, NY 11362.  Employer did not provide eye protection for employees using a compound miter saw.     ABATEMENT VERIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.403 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 30, 2013
Abate by
Aug 5, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:ALLEGED VIOLATION DESCRIPTION (A.V.D.):      a) On or about January 15, 2013- at the site of 52-09 Marathon Parkway Little Neck, NY 11362.    Welder used an installing a breaker connected to a flexible cord and electrical box to power an welding machine.       ABATEMENT VERIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.404 B01 II

Serious Gravity 5 2 instances 5 exposed
Issued
Jul 30, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection:   a) On or about January 15, 2013- at the site of 52-09 Marathon Parkway Little Neck, NY 11362.  Employees were working with damaged flexible cord sets.     ABATEMENT VERIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B04 I

Serious Gravity 5 2 instances 4 exposed
Issued
Jul 30, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes:     a) On or about January 15, 2013- at the site of 52-09 Marathon Parkway Little Neck, NY 11362.        Employer did not provide fall protection open floor hole on the second floor 10-feet 6-inches above the next lower level.       b) On or about January 15, 2013- at the site of 52-09 Marathon Parkway Little Neck, NY 11362.        Employer did not provide fall protection open floor hole on the first floor 8-feet 6-inches above the next lower level.      WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 30, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a) On or about January 15, 2013- at the site of 52-09 Marathon Parkway Little Neck, NY 11362.  Employer did not provide fall protection for employees 12-feet above the next lower level while framing.  WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.503 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 30, 2013
Abate by
Aug 23, 2013
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:    a) On or about January 15, 2013- at the site of 52-09 Marathon Parkway Little Neck, NY 11362.    The Employer could not identify the need for fall protection when employees were exposed to falls of up to 12-feet.     WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 30, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:    a) On or about January 15, 2013- at the site of 52-09 Marathon Parkway Little Neck, NY 11362.    Employees accessing the second floor using a ladder 1-foot above the level being accessed.      WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

View CRJ Builder Corp.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339203127.