LITTLE NECK, NY —
OSHA Inspection: CRJ BUILDER CORP
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CRJ BUILDER CORP in 252-79 LEITH RD, LITTLE NECK, NY 11362 (NAICS 236115). OSHA activity number 340815042.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CRJ BUILDER CORP
- Site address
- 252-79 LEITH RD
- City
- LITTLE NECK
- State
- NY
- ZIP
- 11362
- Mailing
- 254-10 57TH AVE, LITTLE NECK, NY 11362
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 6
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B01 II
- Issued
- Aug 7, 2015
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.451(b)(1)(ii): The platform was not planked or decked as fully as possible and the remaining open space between the platform and the uprights exceeded 9.5 inches (24.1 cm): a) On or about July 31, 2015- job site at 252-79 Leith Road, Little Neck NY 11362 the employer permitted employees to work on a tubular welded frame scaffold that was not fully planked. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.451 C01 I
- Issued
- Aug 7, 2015
- Abate by
- Sep 24, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(1)(i): Guys, ties, and braces were not installed at locations where horixontal members support both inner and outer legs: a) On or about July 31, 2015- job site at 252-79 Leith Road, Little Neck, NY 11362 the employer permitted employees to work on a tubular welded frame scaffold that was missing cross braces and top rails. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 C02 I
- Issued
- Aug 7, 2015
- Abate by
- Sep 24, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement: a) On or about July 31, 2015- job site at 252-79 Leith Road, Little Neck, NY 11362 the employer permitted employees to work on a tubular welded frame scaffold that had its footing on unstable and broken concrete pieces. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01
- Issued
- Aug 7, 2015
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: a) On or about July 31, 2015- job site at 252-79 Leith Road, Little Neck NY 11362 the employer permitted employees to work on a tubular welded frame scaffold, approximately 17 feet above the next lower level, without fall protection. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.451 H02 II
- Issued
- Aug 7, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below:Note: This requirement does not apply to float (ship) scaffolds where an edging of 3/4 inch x 1 1/2 inch (2 x 4 cm) wood or equivalent was used in lieu of toeboards: a) On or about July 17, 2015- job site at 252-79 Leith Road, Little Neck, NY 11362 employer permitted employees to work below a tubular welded frame scaffold, where overhead brick work was being performed, approximately 17 feet above the next lower level, and was not equipped with toeboards. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at CRJ Builder Corp
View CRJ Builder Corp's full OSHA safety record →
More inspections in this industry (NAICS 236115)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340815042.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.