OSHA Inspection: AAP ST. MARYS CORP.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of AAP ST. MARYS CORP. in 1100 MCKINLEY RD., SAINT MARYS, OH 45885 (NAICS 336399). OSHA activity number 339210452.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AAP ST. Marys Corp. — free Get an email when a new federal OSHA severe-injury report for AAP ST. Marys Corp. is published. One employer, no account, unsubscribe in one click.
Establishment
AAP ST. MARYS CORP.
Site address
1100 MCKINLEY RD.
City
SAINT MARYS
State
OH
ZIP
45885
Mailing
1100 MCKINLEY ROAD, SAINT MARYS, OH 45885
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336399
Employees
518
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Deleted Serious Gravity 10 1 instance 500 exposed
Issued
Jan 10, 2014
Penalty
Initial $7,000 · Current $0 Reduced

Hazardous substances L130L131

OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to Legionella bacteria and were at risk of developing Legionnaires' disease.       (a)  AAP St. Marys, St. Marys, Ohio:  On or about July 21, 2013 water samples were collected and later analyzed.  The samples indicated significant levels of Legionella pneumophila bacteria in the east cooling tower and the leak test wheel washer.      Among other methods, one feasible and acceptable abatement method to correct this hazard is to follow:  Cooling Technology Institute, Legionellosis Guideline:  Best Practice for Control of Legionella July 2008 and/or ASHRAE Guideline 12-2000 Minimizing the Risk of Legionellosis Associated with Building Water Systems and (1) feed a source of halogen-based disinfectant (chlorine or bromine) continuously and maintain a free residual, (2) install high efficiency nesting type drift eliminators, and (3) locate cooling towers away from building air intakes in such a manner that cooling tower drift or splash-out is not fed into the building air supply system.
Recent events (3)
  • — F (S) $0
  • — C (S) $7000
  • — Z (S) $7000

View AAP ST. Marys Corp.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339210452.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.