TULSA, OK —
OSHA Inspection: HEAT TRANSFER EQUIPMENT CO.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HEAT TRANSFER EQUIPMENT CO. in 1515 N. 93RD EAST AVE., TULSA, OK 74115 (NAICS 332410). OSHA activity number 339210635.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HEAT TRANSFER EQUIPMENT CO.
- Site address
- 1515 N. 93RD EAST AVE.
- City
- TULSA
- State
- OK
- ZIP
- 74115
- Mailing
- 1515 N. 93RD EAST AVE., TULSA, OK 74115
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332410
- Employees
- 136
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.242 B
- Issued
- Sep 17, 2013
- Abate by
- Sep 25, 2013
- Penalty
- Initial $2,066 · Current $1,240 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: On or about July 17, 2013, and at times prior thereto, in the maintenance shop employees were allowed to use compressed air nozzles for cleaning purpose which were not the type that would reduce the pressure to below 30 p.s.i. The employee was exposed to skin and eye injury.
Recent events (2)
- — I (S) $1239.6
- — Z (S) $2066
1910.303 B02
- Issued
- Sep 17, 2013
- Abate by
- Sep 25, 2013
- Penalty
- Initial $2,066 · Current $1,240 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On or about July 17, 2013, and at times prior thereto, at the VTEC Drill areas a relocatable-power-tap (RPT) was observed being used not in accordance with the listing instruction, exposing employees to fire hazards.
Recent events (2)
- — I (S) $1239.6
- — Z (S) $2066
1910.304 B02
- Issued
- Sep 17, 2013
- Abate by
- Sep 19, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(b)(2): Outlet devices had an ampere rating less than the load being served: On or about July 17, 2013, or at times prior thereto, in the break room electrical equipment were observed plugged into the same outlet device which had a current rating less than the load being served. This exposed employees to fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.179 G01 V
- Issued
- Sep 17, 2013
- Abate by
- Oct 2, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(g)(1)(v): Pendant control box(es) were not clearly marked for identification of functions: On or about July 17, 2013, and at times prior thereto, at the 40 King Mill areas an overhead crane pendant control boxe was observed having the control buttons not clearly marked for identification and function. The employees were exposed to hazards of dropped on and/or struck by materials.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Heat Transfer Equipment CO.
View Heat Transfer Equipment CO.'s full OSHA safety record →
More inspections in this industry (NAICS 332410)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339210635.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.