Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HEAT TRANSFER EQUIPMENT CO.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HEAT TRANSFER EQUIPMENT CO. in 1515 N. 93RD EAST AVE., TULSA, OK 74115 (NAICS 332410). OSHA activity number 339210635.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Heat Transfer Equipment CO. — free Get an email when a new federal OSHA severe-injury report for Heat Transfer Equipment CO. is published. One employer, no account, unsubscribe in one click.
Site address
1515 N. 93RD EAST AVE.
City
TULSA
State
OK
ZIP
74115
Mailing
1515 N. 93RD EAST AVE., TULSA, OK 74115
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332410
Employees
136
Ownership type
A

4 citations on file for this inspection.

1910.242 B

Serious Gravity 1 2 instances 2 exposed
Issued
Sep 17, 2013
Abate by
Sep 25, 2013
Penalty
Initial $2,066 · Current $1,240 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:   On or about July 17, 2013, and at times prior thereto, in the maintenance shop employees were allowed to use compressed air nozzles for cleaning purpose which were not the type that would reduce the pressure to below 30 p.s.i.  The employee was exposed to skin and eye injury.
Recent events (2)
  • — I (S) $1239.6
  • — Z (S) $2066

1910.303 B02

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 17, 2013
Abate by
Sep 25, 2013
Penalty
Initial $2,066 · Current $1,240 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    On or about July 17, 2013, and at times prior thereto, at the VTEC Drill areas a relocatable-power-tap (RPT) was observed being used not in accordance with the listing instruction, exposing employees to fire hazards.
Recent events (2)
  • — I (S) $1239.6
  • — Z (S) $2066

1910.304 B02

Serious Gravity 1 1 instance 25 exposed
Issued
Sep 17, 2013
Abate by
Sep 19, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.304(b)(2): Outlet devices had an ampere rating less than the load being served:   On or about July 17, 2013, or at times prior thereto, in the break room electrical equipment were observed plugged into the same outlet device which had a current rating less than the load being served.  This exposed employees to fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.179 G01 V

Other-than-serious 1 instance 1 exposed
Issued
Sep 17, 2013
Abate by
Oct 2, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.179(g)(1)(v): Pendant control box(es) were not clearly marked for identification of functions:   On or about July 17, 2013, and at times prior thereto, at the 40 King Mill areas an overhead crane pendant control boxe was observed having the control buttons not clearly marked for identification and function.  The employees were exposed to hazards of dropped on and/or struck by materials.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Heat Transfer Equipment CO.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339210635.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.