Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: J CONSTRUCTION, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of J CONSTRUCTION, LLC in 5332 GEORGIA AVE, NW, WASHINGTON, DC 20011 (NAICS 238160). OSHA activity number 339213514.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J Construction, LLC — free Get an email when a new federal OSHA severe-injury report for J Construction, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
J CONSTRUCTION, LLC
Site address
5332 GEORGIA AVE, NW
City
WASHINGTON
State
DC
ZIP
20011
Mailing
1701 DAYTON ROAD, HYATTSVILLE, MD 20783
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.102 A01

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 2, 2013
Abate by
Aug 8, 2013
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.102(a)(1): Employees shall be provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents:   a) Roof of the Building - Roofers were observed without eye protection cutting sheets of plywood exposing them to a potential eye hazard, on or about 07/17/13.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $1200

1926.416 A01

Serious Gravity 5 1 instance 5 exposed
Issued
Aug 2, 2013
Abate by
Aug 8, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:   a) West Side of the Roof - Roofers were observed working in close proximity of unprotected energized electrical lines, 220 volt 200 ampere exposing them to a potential electrical hazard, on r about 07/17/13.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $2000

1926.501 B10

Serious Gravity 5 1 instance 5 exposed
Issued
Aug 2, 2013
Abate by
Aug 8, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system:   a) Roof of the Building - A foreman and roofers were observed without fall protection performing roofing operations exposing them to a 22 foot fall hazard, on or about 07/17/13.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $2000

1926.1053 B01

Serious Gravity 5 1 instance 5 exposed
Issued
Aug 2, 2013
Penalty
Initial $1,360 · Current $1,360
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:   a) North Side of the Building - A foreman and roofers were observed using an extension ladder which was only extended 28 inches past the top of the parapet wall exposing them to a 22 foot fall hazard, on or about 07/17/13.
Recent events (1)
  • — Z (S) $1360

View J Construction, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339213514.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.