Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MARSAM METAL FINISHING COMPANY, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MARSAM METAL FINISHING COMPANY, INC. in 28 HARVARD STREET, NEW BRITAIN, CT 06051 (NAICS 332813). OSHA activity number 339219842.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Marsam Metal Finishing Company, INC. — free Get an email when a new federal OSHA severe-injury report for Marsam Metal Finishing Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
28 HARVARD STREET
City
NEW BRITAIN
State
CT
ZIP
06051
Mailing
28 HARVARD STREET, NEW BRITAIN, CT 06051
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
39
Ownership type
A

4 citations on file for this inspection.

1910.303 B02

Serious Gravity 5 2 instances 4 exposed
Issued
Aug 8, 2013
Abate by
Sep 25, 2013
Penalty
Initial $2,142 · Current $1,071 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  Blasting Department:  On, or about, July 18, 2013, the following electrical equipment was not used or installed in accordance with its listing or labeling:  A.     Rotary Tumbling Area:  A Lasko box fan designed for use in a residential location was used for general ventilation in the work area.  B.     Electrical Room:  A piece of plexiglass was used in lieu of the proper trim plate on the Square D panelboard.
Recent events (2)
  • — I (S) $1071
  • — Z (S) $2142

1910.303 B07 I

Serious Gravity 5 4 instances 4 exposed
Issued
Aug 8, 2013
Abate by
Sep 25, 2013
Penalty
Initial $2,142 · Current $1,071 Reduced
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxillary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substanially equivalent to the wall of the equipment:  Blasting Department, Electrical Room:  On, or about, July 18, 2013, four openings were left in the face of the GE 480 volt panelboard above and below the installed overcurrent devices.
Recent events (2)
  • — I (S) $1071
  • — Z (S) $2142

1910.303 G01 V

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 8, 2013
Abate by
Sep 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(v): Illumination was not provided for all working spaces about service equipment, swtichboards, panelboards, and motor control centers installed indoors:   Blasting Department:  On, or about, July 18, 2013, the light fixture provided in the Electrical Room was not in working order.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 F02

Serious Gravity 1 2 instances 4 exposed
Issued
Aug 8, 2013
Abate by
Sep 25, 2013
Penalty
Initial $1,607 · Current $804 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  Blasting Department Electrical Room:  On, or about, July 18, 2013, the individual circuit breakers/overcurrent devices provided in the GE and Square D panelboards were not labeled to indicate their purpose.
Recent events (2)
  • — I (S) $803.5
  • — Z (S) $1607

View Marsam Metal Finishing Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339219842.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.