Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CFI CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CFI CONSTRUCTION, INC. in VILLAGE OF COOPERSTOWN WASTEWATER TREATMENT FACILITY, 213 LINDEN AVE., COOPERSTOWN, NY 13326 (NAICS 237110). OSHA activity number 339221616.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CFI Construction, INC. — free Get an email when a new federal OSHA severe-injury report for CFI Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
VILLAGE OF COOPERSTOWN WASTEWATER TREATMENT FACILITY, 213 LINDEN AVE.
City
COOPERSTOWN
State
NY
ZIP
13326
Mailing
286 SACANDAGA ROAD, JOHNSTOWN, NY 12095
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
4
Ownership type
A

4 citations on file for this inspection.

1926.21 B06 I

Deleted Serious Gravity 5 2 instances 2 exposed
Issued
Aug 2, 2013
Abate by
Aug 12, 2013
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1926.21(b)(6)(i): Employees required to enter into confined or enclosed spaces were not instructed as to the nature of the hazards involved, the necessary precautions to be taken, and in the use of protective and emergency equipment required:  a) Inside of tank, on or about 7-19-13:  Employees worked inside a confined space (sewage/waste storage tank) without being instructed as to the nature of the hazards involved, the necessary precautions to be taken, and in the use of protective and emergency equipment required for retrieval of personnel.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3500

1926.300 B01

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Aug 2, 2013
Abate by
Aug 12, 2013
Penalty
Initial $2,100 · Current $0 Reduced
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use:   a) Southeast corner of building, on or about 7-12-13:  One employee was cleaning a weld while using a hand held portable grinder that was not equipped with a protective guard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2100

1926.404 B01 II

Other-than-serious 1 instance 4 exposed
Issued
Aug 2, 2013
Abate by
Aug 12, 2013
Penalty
Initial $2,100 · Current $1,100 Reduced
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection:    a) Southeast corner of building, roof, on or about 7-12-13:  One employee was using a hand held portable electric grinder that was not protected by a ground fault circuit interrupter (GFCI).    b) Top of tank,  on or about 7-12-13:  Four employees were using a large metal cased box fan that was not protected by a ground fault circuit interrupter (GFCI).
Recent events (2)
  • — I (O) $1100
  • — Z (S) $2100

1926.502 D16 III

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Aug 2, 2013
Abate by
Aug 12, 2013
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level:  a) Southeast corner of building, roof, on or about 7-12-13:  One employee was working on the roof with a fall protection system that would allow a free fall of 12 feet 9 inches.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

View CFI Construction, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339221616.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.