OSHA Inspection: LASER FABRICATION & MACHINE CO., INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of LASER FABRICATION & MACHINE CO., INC. in 14055 U.S. HIGHWAY 431, WELLINGTON, AL 36279 (NAICS 332313). OSHA activity number 339230328.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Laser Fabrication & Machine CO., INC. — free Get an email when a new federal OSHA severe-injury report for Laser Fabrication & Machine CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
14055 U.S. HIGHWAY 431
City
WELLINGTON
State
AL
ZIP
36279
Mailing
P.O. BOX 709, ALEXANDRIA, AL 36250
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332313
Employees
63
Ownership type
A

10 citations on file for this inspection.

1910.95 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 8, 2013
Abate by
Jan 14, 2014
Penalty
Initial $2,800 · Current $1,680 Reduced

Hazardous substances 8111

29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent:    a) On or about 7/25/13 - Grinding area, a machinist was exposed to continuous noise levels at 96.3 percent of the allowable 8-hour time-weighted average of 80 dBA or an equivalent sound level of approximately 89.7 dBA. The sampling was performed for 470 minutes on 7/30/13.  Zero exposure was assumed for the remainder of the shift (10 minutes).    b) On or about 7/25/13 - Grinding area, a machinist was exposed to continuous noise levels at 79.6 percent of the allowable 8-hour time-weighted average of 80 dBA or an equivalent sound level of approximately 88.1 dBA. The sampling was performed for 477 minutes on 7/30/13.  Zero exposure was assumed for the remainder of the shift (3 minutes).
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.107 B05 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 8, 2013
Penalty
Initial $2,800 · Current $1,680 Reduced

Hazardous substances 2440

29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers:    a) On or about 7/25/13 - Coating area, Binks front flow spray booth, the booth used for the application of combustible and flammable electrostatic powder coatings was not equipped with an automatic sprinkler.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.107 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 8, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 2440

29 CFR 1910.107(b)(9): A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction:  a) On or about 7/25/13 - Coating area, Binks front flow spray booth, a clear space of not less than 3 feet was not maintained on all sides.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 E05

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 8, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 2440

29 CFR 1910.107(e)(5): Spraying container(s) were not provided with a visible pressure gauge:  a) On or about 7/25/13 - Coating area, an Optiflex 2 type CG09 electrostatic sprayer, SN# 20301.00083, had a pressure gauge that was not visible.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 F04

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 8, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 2440

29 CFR 1910.107(f)(4): An adequate supply of suitable portable fire extinguishers were not installed near all spraying areas:   a) On or about 7/25/13 - Coating area, a Binks front flow spray booth, fire extinguishers were not installed near the spraying area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 G02

Serious Gravity 5 2 instances 1 exposed
Issued
Nov 8, 2013
Abate by
Nov 24, 2013
Penalty
Initial $2,800 · Current $1,680 Reduced

Hazardous substances 2440

29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. Scrapers, spuds or other such tools used for cleaning purposes shall be composed of non-sparking material:    a) On or about 7/25/13 - Coating area, Binks front flow spray booth, combustible residue was allowed to accumulate to a depth of 1.5 inches and an aluminum shovel was used for cleaning.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.107 G07

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 8, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 2440

29 CFR 1910.107(g)(7): "No smoking" signs in large letters on contrasting color backgrounds were not conspicuously posted at all spraying areas and the paint storage rooms:  a) On or about 7/25/13 - Coating area, "No smoking" signs were not posted.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.138 A

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 8, 2013
Abate by
Nov 21, 2013
Penalty
Initial $2,100 · Current $1,260 Reduced

Hazardous substances 2085

29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion:    a) On or about 7/25/13 - Lower production building, priming area, acid-resistant gloves were not selected and required for an employee spraying and washing off phosphoric acid from metal parts.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2100

1910.151 C

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 8, 2013
Abate by
Nov 29, 2013
Penalty
Initial $2,800 · Current $1,680 Reduced

Hazardous substances 2085

29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    a) On or about 7/25/13 - Priming area, a painter was spraying corrosive chemical solutions to steel plates.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.134 C01

Other-than-serious 5 instances 14 exposed
Issued
Nov 8, 2013
Abate by
Jan 14, 2014
Penalty
Initial $0 · Current $0

Hazardous substances 07300731152020852440

29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i)- (ix) with worksite specific procedures was not established and implemented for required respirator use:    a) On or about 7/25/13 - Facility, a written respiratory program had not been established or implemented for an employee wearing a 3M 8577 particulate respirator while applying electrostatic coatings in the paint booth.     b) On or about 7/25/13 - Facility, a written respiratory program had not been established or implemented for an employee wearing a 3M 8577 particulate respirator while spraying and washing off phosphoric acid in the metal parts priming area.     c) On or about 7/25/13 - Facility, a written respiratory program had not been established or implemented  for employees machining aluminum parts at the welding area of the lower production building.     d) On or about 7/25/13 - Facility, a written respiratory program had not been established or implemented for employees welding aluminum parts at the welding area of the lower production building.     e) On or about 7/25/13 - Facility, a written respiratory program had not been established or implemented for employees welding steel parts in the welding area of the lower production building.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0