LAWRENCE, KS —
OSHA Inspection: SCREEN IT GRAPHICS OF LAWRENCE, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SCREEN IT GRAPHICS OF LAWRENCE, INC. in 3840 GREENWAY CIRCLE, LAWRENCE, KS 66046 (NAICS 323113). OSHA activity number 339241747.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SCREEN IT GRAPHICS OF LAWRENCE, INC.
- Site address
- 3840 GREENWAY CIRCLE
- City
- LAWRENCE
- State
- KS
- ZIP
- 66046
- Mailing
- 3840 GREENWAY CIRCLE, LAWRENCE, KS 66046
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323113
- Employees
- 95
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.147 C01
- Issued
- Dec 16, 2013
- Abate by
- Jun 16, 2014
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: An employee engaged in maintenance activities throughout the workplace was exposed to electrical shock, struck-by and caught-between hazards while performing maintenance on the printing presses and ovens in that a comprehensive energy control program had not been developed and implemented.
Recent events (3)
- — F (S) $1750
- — C (S) $3500
- — Z (S) $3500
1910.212 A01
- Issued
- Dec 16, 2013
- Abate by
- Jun 16, 2014
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Employees engaged in printing press operation activities at press #G3 in the Print and Stack Department were exposed to caught-between hazards in that the sprocket and slide at the rear of the machine was not guarded.
Recent events (3)
- — F (S) $1400
- — C (S) $2800
- — Z (S) $2800
1910.219 F03
- Issued
- Dec 16, 2013
- Penalty
- Initial $2,100 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven 7 feet or less above floors or platforms were not enclosed: Employees engaged in production activities at the Precision Oven in the Production Area were exposed to caught-between hazards in that the chain and sprocket wheel assembly on the north east corner of the oven was not guarded.
Recent events (3)
- — F (S) $1050
- — C (S) $2100
- — Z (S) $2100
1910.303 B01 II
- Issued
- Dec 16, 2013
- Penalty
- Initial $2,100 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided: Employees engaged in production activities in the Production Area were exposed to electrical shock hazards in that the following electrical sources were not free from recognized hazards: a) Employees engaged in printing activities at press #G3 in the Print and Stack Department were exposed to electrical shock hazards in that the flexible cord supplying power to the press had been damaged and covered using white tape. b) Employees engaged in production activities at the Precision Oven in the Production Area were exposed to electrical hazards in that the flexible cord supplying power to the oven had been spliced together using wire nuts and was not in conduit.
Recent events (3)
- — F (S) $1050
- — C (S) $2100
- — Z (S) $2100
1910.303 B07 I
- Issued
- Dec 16, 2013
- Penalty
- Initial $2,100 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment: An employee engaged in ink milling activities at the Kent Ink Mill in the Ink and Screen Room was exposed to electrical shock and fire hazards in that two knockouts were missing on a junction box located on the wall above the ink mill.
Recent events (3)
- — F (S) $1050
- — C (S) $2100
- — Z (S) $2100
1910.303 G02 I B
- Issued
- Dec 16, 2013
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i)(B): Except as elsewhere required or permitted by this standard, live parts of electrical equipment operating at 50 volts or more was not guarded by suitable permanent, substantial partitions or screens so arranged so that only qualified persons would have access to the space within reach of the live parts. Any openings in such partitions or screens were not so sized and located that persons were not likely to come into accidental contact with the live parts or to bring conducting objects into contact with them: Employees engaged in production activities throughout the Production Area were exposed to electrical shock hazards in that the following live electrical sources were not protected: a) The terminal compartment panel at the Lehr 2 oven was missing, the location was marked as high voltage, 480 volt. b) Two junction boxes at the Precision oven were missing covers. c) A thermostat control at the Precision oven was missing a cover. d) The electrical cover at press #G3 was missing.
Recent events (3)
- — F (S) $1750
- — C (S) $3500
- — Z (S) $3500
1910.303 B02
- Issued
- Dec 16, 2013
- Abate by
- Jun 16, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: At press #G2 in the Print and Stack Department, the Belkin relocatable power tap supplying power to the press, the hot box, and a fan located on top of the press was not listed for industrial use.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at Screen IT Graphics of Lawrence, INC.
View Screen IT Graphics of Lawrence, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 323113)
More inspections in KS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339241747.