On , OSHA opened a complaint safety inspection of LENCO PMC in 5000 DOUGLAS DRIVE, LINCOLN, NE 68504 (NAICS 493190). OSHA activity number 339244865.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lenco PMC — free Get an email when a new federal OSHA severe-injury report for Lenco PMC is published. One employer, no account, unsubscribe in one click.
Establishment
LENCO PMC
Site address
5000 DOUGLAS DRIVE
City
LINCOLN
State
NE
ZIP
68504
Mailing
10240 DEER PARK ROAD, WAVERLY, NE 68462
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493190
Employees
4
Ownership type
A

2 citations on file for this inspection.

1910.178 G02

Serious Gravity 5 3 instances 2 exposed
Issued
Sep 26, 2013
Abate by
Oct 23, 2013
Penalty
Initial $3,443 · Current $1,722 Reduced
29 CFR 1910.178(g)(2): Battery charging apparatus for industrial trucks located in battery changing and charging installation was not protected from damage by trucks:    In Forklift Battery Charging Area: The employer failed to provide protection for the forklift battery chargers in that the units are located on the floor and there are not guards to prevent accidental contact by forklifts.
Recent events (2)
  • — I (S) $1721.5
  • — Z (S) $3443

1910.305 G01 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 26, 2013
Abate by
Oct 23, 2013
Penalty
Initial $2,754 · Current $1,652 Reduced
29 CFR 1910.305(g)(1)(iv): Flexible cords were used in a manner not permitted in paragraph (g)(1)(ii):      At Lenco PMC: The employer allowed a flexible cord to wire  a permanent installation. A red 120v flexible cord was used to energize a power strip in order to provide power to a refridgerator, microwave and coffee pot used by employees.    1910.305(g)(1)(iv)       [A]- prohibits flexible cords to be used as substitute for fixed permanent installations  [D]- prohibits flexible wiring to be attached to building surfaces