Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NORTHERN REPAIR AND WELDING

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NORTHERN REPAIR AND WELDING in R15300 RINGLE AVENUE, RINGLE, WI 54471 (NAICS 811310). OSHA activity number 339245540.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Northern Repair and Welding — free Get an email when a new federal OSHA severe-injury report for Northern Repair and Welding is published. One employer, no account, unsubscribe in one click.
Site address
R15300 RINGLE AVENUE
City
RINGLE
State
WI
ZIP
54471
Mailing
R15300 RINGLE AVENUE, RINGLE, WI 54471
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
30
Ownership type
A

7 citations on file for this inspection.

1910.178 A06

Serious Gravity 5 2 instances 4 exposed
Issued
Jan 3, 2014
Abate by
Feb 10, 2014
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates or markings were maintained in a legible condition:     a)      On and or about 07-31-13, employees were operating a Clark forklift without a legible name plate and markings.     b)      On and or about 07-31-13, employees were operating a Yale forklift without a legible name plate and markings.       ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • — F (S) $1400
  • — C (S) $2800
  • — Z (S) $2800

1910.178 P01

Serious Gravity 5 3 instances 4 exposed
Issued
Jan 3, 2014
Abate by
Feb 10, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s):     a)      On and or about 07-31-13, employees were operating a Clark LP forklift without a working horn.  b)      On and or about 07-31-13, employees were operating a Yale LP forklift without a working horn.  c)      On and or about 07-31-13, employees were operating a Daewoo diesel forklift without a working horn.   ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.178 Q07

Serious Gravity 5 4 instances 4 exposed
Issued
Jan 3, 2014
Abate by
Feb 10, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service:    a)      On and or about 07-31-13, employees in a welding repair shop were operating a Clark LP forklift without a working horn and without any backup warning device.  b)      On and or about 07-31-13, employees in a welding repair shop were operating a Yale stock number 304 LP forklift without a working horn and without any backup warning device.   c)      On and or about 07-31-13, employees in a welding repair shop were operating a Yale GLP100MGNGBE093 forklift without a backup warning device and with a damaged seat belt.   d)     On and or about 07-31-13, employees in a welding repair shop were operating a Daewoo diesel forklift without a working horn, without any backup warning device, and with a damaged seatbelt.    ABATEMENT CERTIFICATION REQUIRED.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.303 G01 II

Serious Gravity 5 2 instances 10 exposed
Issued
Jan 3, 2014
Abate by
Feb 10, 2014
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:     a)      On and or about 07-31-13, electric panel in the tool room had buckets and equipment stored within two (2) feet of the front of the panel.   b)      On and or about 07-31-13, electric panel in the shop room had materials stored within two (2) feet of the front of the panel.       ABATEMENT CERTIFICATION REQUIRED.
Recent events (3)
  • — F (S) $1750
  • — C (S) $3500
  • — Z (S) $3500

1910.304 G05

Serious Gravity 5 2 instances 4 exposed
Issued
Jan 3, 2014
Abate by
Feb 10, 2014
Penalty
Initial $4,200 · Current $2,100 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    a)      On and or about 07-31-13, employees were using an Evolution Raptor 355 metal cutting chop saw without a ground pin.    b)      On and or about 07-31-13, employers were using extension cords without ground pins to power a handheld grinders.        ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • — F (S) $2100
  • — C (S) $4200
  • — Z (S) $4200

1910.305 G02 II

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 3, 2014
Abate by
Feb 10, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:    a)      On and or about 07-31-13, employees were using a spliced extension cord to power a handy box mounted on a four wheeled cart as the electrical power outlet for a chop saw.    ABATEMENT CERTIFICATION REQUIRED.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.334 A02 I

Serious Gravity 5 3 instances 2 exposed
Issued
Jan 3, 2014
Abate by
Feb 10, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  a)      On and or about 07-31-13, employer and/or employees did not inspect an Evolution Raptor 355 metal cutting chop saw prior to use; the plug was missing a ground pin during use.  b)      On and or about 07-31-13, employer and/or employees did not inspect an extension cord powering a handy box mounted on a portable cart prior to use; the cord was spliced.  c)      On and or about 07-31-13, employer and/or employees did not inspect extension cords prior to use; the cords were missing ground pins.      ABATEMENT CERTIFICATION REQUIRED.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

View Northern Repair and Welding's full OSHA safety record →