Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NORTHERN REPAIR AND WELDING

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of NORTHERN REPAIR AND WELDING in R15300 RINGLE AVE, RINGLE, WI 54471 (NAICS 333111). OSHA activity number 341972453.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Northern Repair and Welding — free Get an email when a new federal OSHA severe-injury report for Northern Repair and Welding is published. One employer, no account, unsubscribe in one click.
Site address
R15300 RINGLE AVE
City
RINGLE
State
WI
ZIP
54471
Mailing
R15300 RINGLE AVENUE, RINGLE, WI 54471
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333111
Employees
23
Ownership type
A

8 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 20 exposed
Issued
Oct 17, 2018
Abate by
Nov 15, 2018
Penalty
Initial $1,037 · Current $1,037
29 CFR 1903.19(c)(1):   The employer failed to certify to OSHA (the Agency) that the following item(s) were abated within 10 calendar days after the abatement date:  Northern Repair and Welding, did not provide abatement certification within 10 calendar days after the abatement date on all the cited items.
Recent events (1)
  • — Z (O) $1037

1903.19 D01

Other-than-serious 6 instances 20 exposed
Issued
Oct 17, 2018
Abate by
Nov 15, 2018
Penalty
Initial $0 · Current $0
29 CFR 1903.19(d)(1): The employer must submit to the Agency, along with the information on abatement certification required by paragraph (c)(3) of this section, documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required.   Norhtern Repair and Welding, failed to provide documentation demonstrating the abatement method and completion of the cited items.
Recent events (1)
  • — Z (O) $0

1910.23 C01

Serious Gravity 10 1 instance 20 exposed
Issued
Jan 19, 2017
Abate by
Feb 16, 2017
Penalty
Initial $5,070 · Current $2,000 Reduced
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder.     Northern Repair and Welding facility located at R15300 Ringle Ave. Ringle, WI: On or about December 14, 2016, employees were exposed to 4 feet and greater fall hazards while working on elevated surfaces, including but not limited to, tanker type trailer equipment when perimeter guardrails were not provided.  Other feasible alternative means of fall protection such as temporary guarded scaffolding or the use of personal fall protection systems were not used to protect employee from falls.
Recent events (3)
  • — F (S) $2000
  • — C (S) $5070
  • — Z (S) $5070

1910.132 D01 I

Serious Gravity 10 1 instance 20 exposed
Issued
Jan 19, 2017
Abate by
Feb 16, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 00400689137716752440

29 CFR 1910.132(d)(1): The employer shall assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). If such hazards are present, or likely to be present, the employer shall: (i) Select, and have each affected employee use, the types of PPE that will protect the affected employee from the hazards identified in the hazard assessment;  Northern Repair and Welding facility located at R15300 Ringle Ave, Ringle, WI: On or about December 14, 2016, employees were exposed to fall hazards and respiratory hazards when the employer's assessment of the workplace did not identify the hazards or corrective measures to prevent:  A) falls from elevated working surfaces;  B)  exposure to hazardous chemicals containing Isocyanates;  C: exposure to hazardous environments while working in permit required confined spaces.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.134 C01

Serious Gravity 10 1 instance 20 exposed
Issued
Jan 19, 2017
Abate by
Feb 16, 2017
Penalty
Initial $5,070 · Current $2,000 Reduced

Hazardous substances 00400689137716752440

29 CFR 1910.134(c)(1): In any workplace where respirators are necessary to protect the health of the employee or whenever respirators are required by the employer, the employer shall establish and implement a written respiratory protection program with worksite-specific procedures. The program shall be updated as necessary to reflect those changes in workplace conditions that affect respirator use. The employer shall include in the program the following provisions of this section, as applicable:    Northern Repair and Welding facility located at R15300 Ringle Ave, Ringle, WI: On or about December 14, 2016, the employer had not implemented a written respiratory program and painters were exposed to metal coating operations containing Isocyanates and solvents.  Employees were provided with respirators but they had not been medically evaluated, fit tested, or trained to properly wear respirators, and welders welding stainless steel were not provided with appropriate type respiratory protection to protect them from Hexavalent Chromium fume.
Recent events (3)
  • — F (S) $2000
  • — C (S) $5070
  • — Z (S) $5070

1910.252 B04 II

Serious Gravity 10 1 instance 20 exposed
Issued
Jan 19, 2017
Abate by
Feb 16, 2017
Penalty
Initial $5,070 · Current $2,000 Reduced

Hazardous substances 0530068914801640

29 CFR 1910.252(b)(4)(ii): Ventilation. Ventilation is a prerequisite to work in confined spaces. For ventilation requirements see paragraph (c) of this section.    Northern Repair and Welding facility located at R15300 Ringle Ave. Ringle, WI: On and before December 14, 2016, the employer did not ensure that employees welding in confined spaces used adequate ventilation to ensure safe atmospheres were maintained throughout the duration of the work.
Recent events (3)
  • — F (S) $2000
  • — C (S) $5070
  • — Z (S) $5070

1910.252 B04 IV

Serious Gravity 10 1 instance 20 exposed
Issued
Jan 19, 2017
Abate by
Feb 16, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 0530068914801640

29 CFR 1910.252(b)(4)(iv): Lifelines. Where a welder must enter a confined space through a manhole or other small opening, means shall be provided for quickly removing him in case of emergency. When safety belts and lifelines are used for this purpose they shall be so attached to the welder's body that his body cannot be jammed in a small exit opening. An attendant with a preplanned rescue procedure shall be stationed outside to observe the welder at all times and be capable of putting rescue operations into effect.  Northern Repair and Welding facility located at R15300 Ringle Ave. Ringle, WI: On or about December 14, 2016, the employer did not ensure that employees welding in confined spaces were  provided with an outside attendants to monitor their work inside those spaces and to provide attendant with a preplanned rescue procedures and equipment to retrieve workers quickly and safely from the space in the event of an emergency.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.303 G01 II

Repeat Gravity 5 1 instance 20 exposed
Issued
Jan 19, 2017
Abate by
Feb 16, 2017
Penalty
Initial $5,794 · Current $3,600 Reduced
29 CFR 1910.303(g)(1)(ii): Working space required by this standard may not be used for storage. When normally enclosed live parts are exposed for inspection or servicing, the working space, if in a passageway or general open space, shall be suitably guarded.    Northern Repair and Welding facility located at R15300 Ringle Ave. Ringle, WI: On or about December 14, 2016, the employer did not ensure that area in front of and on the both sides of the electrical breaker panel located in the tool room was kept clear at least 3 feet.  Five gallon buckets  of fluid and other equipment was stored in front of electrical panel that obstructed safe access.       Northern Repair and Welding was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 924554, citation number 1, item number 2, and was affirmed as a final order on 3/19/14, with respect to a workplace located at R15300 Ringle Ave. Ringle, WI 54471.
Recent events (3)
  • — F (R) $3600
  • — C (R) $5794
  • — Z (R) $5794

View Northern Repair and Welding's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341972453.