Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: TRIDENT BUILDING SYSTEMS, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of TRIDENT BUILDING SYSTEMS, INC. in 2812 TALLEVAST ROAD, SARASOTA, FL 34243 (NAICS 332311). OSHA activity number 339245763.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Trident Building Systems, INC. for free Get an email when a new federal OSHA severe-injury report for Trident Building Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2812 TALLEVAST ROAD
City
SARASOTA
State
FL
ZIP
34243
Mailing
2812 TALLEVAST RD, SARASOTA, FL 34243
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332311
Employees
92
Ownership type
Private (A)

2 citations on file for this inspection.

1910.95 C01

Other-than-serious 2 instances 12 exposed
Issued
Sep 16, 2013
Abate by
Nov 1, 2013
Penalty
Initial $4,200 · Current $2,580 Reduced

Hazardous substances 81108111

29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent:    For employees working in the shop located at 2812 Tallevast Rd, Sarasota FL 34230:      a.  Employee 1, doing welding and grinding on structural iron beams over the PEMB table next to the safety office was exposed to continuous noise levels at 120.7% of the Action level (8-hour time weighted average sound level of 85 dBA) during a 448 minute sampling period on August 7th, 2013; exposure calculations included a zero increment for the 32 minutes not sampled.    b.  Employee 2, operating the automated twin submerged arc welder was exposed to continuous noise levels at 118% of the Action level (8-hour time weighted average sound level of 85 dBA) during the 452 minute sampling period on August 7th, 2013; exposure calculations included a zero increment for the 28 minutes not sampled.
Recent events (3)
  • · R (O) $2580
  • · C (S) $4200
  • · Z (S) $4200

1910.132 D01

Deleted Other-than-serious 1 instance 12 exposed
Issued
Sep 16, 2013
Abate by
Oct 10, 2013
Penalty
Initial $700 · Current $0 Reduced
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards were present, or were likely to be present, which necessitated the use of personal protective equipment:  a) For employees engaged in welding and grinding of structural iron beams throughout the shop area as observed on or about 08/07/13.  Employees are exposed to burn in arms from the sparks produced from the grinding on iron beams.
Recent events (3)
  • · R (O) $0
  • · C (O) $700
  • · Z (O) $700

View Trident Building Systems, INC.'s full OSHA safety record →