OSHA Inspection: ARCELORMITTAL LAPLACE

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of ARCELORMITTAL LAPLACE in 138 HWY 3217, LA PLACE, LA 70068 (NAICS 331111). OSHA activity number 339245995.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Arcelormittal Laplace — free Get an email when a new federal OSHA severe-injury report for Arcelormittal Laplace is published. One employer, no account, unsubscribe in one click.
Site address
138 HWY 3217
City
LA PLACE
State
LA
ZIP
70068
Mailing
138 HWY 3217, LA PLACE, LA 70068
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331111
Employees
410
Ownership type
A

3 citations on file for this inspection.

1910.1025 H01

Serious Gravity 10 1 instance 2 exposed
Issued
Dec 27, 2013
Abate by
Jan 16, 2014
Penalty
Initial $7,000 · Current $4,900 Reduced
29 CFR 1910.1025(h)(1): All surfaces were not maintained as free as practicable of accumulations of lead:    On or about 9/24/2013, in the north charging crane cab of the melt shop, the employer allowed employees to work, eat, and drink in the crane cab with elevated levels of surface lead contamination.
Recent events (2)
  • — I (S) $4900
  • — Z (S) $7000

1910.1025 H02 I

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 27, 2013
Abate by
Mar 31, 2014
Penalty
Initial $7,000 · Current $4,900 Reduced
29 CFR 1910.1025(h)(2)(i): Floors and/or other surfaces where lead accumulates were cleaned by the use of compressed air: Employees use compressed air to clean the brake assembly of the charging crane in the melt shop.     On or about 08/21/2013, the employer allowed an employee to clean the brake assembly of the north charging crane in the melt shop using compressed air in order to remove dust from the assembly which interferes with crane braking.
Recent events (2)
  • — I (S) $4900
  • — Z (S) $7000

1910.303 F02

Other-than-serious 1 instance 9 exposed
Issued
Dec 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: A breaker box in the lunch area of the Electric Arc Furnace pulpit did not have labeling indicating its purpose.   On or about 08/21/13, in the Electric Arc Furnace pulpit, the breaker box for the Electric Arc Furnace Pulpit did not have legible labels indicating the breakers' purpose.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Arcelormittal Laplace's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339245995.