Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EMERALD COAST RV CENTER, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of EMERALD COAST RV CENTER, LLC in 21282 HIGHWAY 59 SOUTH, ROBERTSDALE, AL 36567 (NAICS 441210). OSHA activity number 339248163.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Emerald Coast RV Center, LLC — free Get an email when a new federal OSHA severe-injury report for Emerald Coast RV Center, LLC is published. One employer, no account, unsubscribe in one click.
Site address
21282 HIGHWAY 59 SOUTH
City
ROBERTSDALE
State
AL
ZIP
36567
Mailing
21282 HIGHWAY 59 SOUTH, ROBERTSDALE, AL 36567
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441210
Employees
46
Ownership type
A

11 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 5, 2013
Abate by
Dec 13, 2013
Penalty
Initial $4,000 · Current $2,500 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent).   a)  Shop Area: On or about August 2, 2013 and at times prior; the employer failed to provide fall protection such as but not limited to guardrails or personal fall arrest systems to protect employees from falls of up to 12 feet while working on top of recreational vehicles.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $4000

1910.178 L01 I

Serious Gravity 10 1 instance 2 exposed
Issued
Dec 5, 2013
Abate by
Dec 13, 2013
Penalty
Initial $7,000 · Current $3,000 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).   a)   On or about August 2, 2013 and at times prior; the employer exposed employees to struck-by hazards in that employees were allowed to operate a powered industrial truck without the employer first ensuring the employees were competent to operate the equipment as demonstrated by the completion of the required training and evaluation specified in the regulation.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $7000

1910.213 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 5, 2013
Abate by
Dec 13, 2013
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut.   a)Shop Area: On or about August 2, 2013 and at times prior; employees were exposed to amputation hazards when operating a table saw without a guard.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $5000

1910.242 B

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 5, 2013
Abate by
Dec 13, 2013
Penalty
Initial $4,000 · Current $2,500 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.  a)  Shop area:  On or about August 2, 2013 and at times prior; the employer exposed his employees to compressed air hazards in that employees were permitted to use compressed air that was not reduced to less than 30 psi for cleaning.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $4000

1910.253 B02 II

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 5, 2013
Abate by
Dec 13, 2013
Penalty
Initial $4,000 · Current $2,500 Reduced
29 CFR 1910.253(b)(2)(ii):  Cylinders were not stored in areas that the cylinders would not be knocked over.  a)  Shop Area:  On or about August 2, 2013 and at times prior; the employer exposed employees to struck by hazards in that employees were allowed to walk and work in the same area where cylinders were stored but were not secured to prevent the cylinders from being knocked over.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $4000

1910.305 B01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 5, 2013
Abate by
Dec 13, 2013
Penalty
Initial $4,000 · Current $2,500 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed.   a)  Shop Area: On or about August 2, 2013 and at times prior; the employer exposed his employees to arc blast and fire hazards in that the employees were allowed to walk and work around the electrical box that is missing  a breaker blank.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $4000

1910.305 B02 I

Serious Gravity 5 2 instances 1 exposed
Issued
Dec 5, 2013
Abate by
Dec 13, 2013
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy.   a)  Shop Area, Bay 4: On or about August 2, 2013 and at times prior; the employer exposed his employees to electrocution hazards in that the employees were allowed to plug the recreational vehicles in a 110 V outlet that is missing the faceplate.   b)  Shop Area, end of Bay 4: On or about August 2, 2013 and at times prior; the employer exposed his employees to electrocution hazards in that the employees were allowed to use, walk and/or work an outlet that is missing the faceplate.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $5000

1910.305 G01 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 5, 2013
Abate by
Dec 13, 2013
Penalty
Initial $4,000 · Current $2,500 Reduced
29 CFR 1910.305(g)(1)(iv): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used as a substitute for the fixed wiring of a structure.   a) Shop Area: On August 2, 2013 and at times prior; the employer exposed employees to electrical or fire hazards by allowing temporary wiring (extension cords) that run through the wall and frames of the building to be used as permanent wiring to provide power to several appliances in the shop.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $4000

1910.1200 E01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 5, 2013
Abate by
Dec 13, 2013
Penalty
Initial $4,000 · Current $2,500 Reduced
29 CFR 1910.1200(e)(1)(i): The written hazard communication program did not include a list of the hazardous chemicals known to be present, using an identity that was referenced on the appropriate material safety data sheet:   (a) Shop Area:  On or about August 2, 2013 and at times prior; the employer exposed employees to burns, intoxication and/or fire hazards in that employees were allowed to handle chemicals like oxygen, acetylene, argon, recreational vehicles batteries containing sulfuric acid, paints, diesel and chemical cleaners without being provided with a list of the hazardous chemicals available on site.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $4000

1910.1200 H01

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 5, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area.   (a) Shop area:  On or about August 2, 2013 and at times prior; the employer exposed employees to burns, intoxication and/or fire hazards in that employees were allowed to handle chemicals like oxygen, acetylene, argon, recreational vehicles batteries containing sulfuric acid, paints, diesel and chemical cleaners without trained on the methods that may be used to protect themselves from health and safety hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C02

Other-than-serious 1 instance 3 exposed
Issued
Dec 5, 2013
Abate by
Dec 13, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2): The employer did not develop and implement a respiratory protection program in accordance with sections i and ii of this paragraph (c)(2) for employees who chose to wear respirators where respirator use was not required.  a) Shoparea:  On or about August 2, 2013 the employer failed to develop and implement a written respiratory protection program exposing the employees who use respirator to respiratory hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Emerald Coast RV Center, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339248163.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.