Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SOUTHERN FOREST INDUSTRIES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SOUTHERN FOREST INDUSTRIES, INC. in 3794 OLD MACON ROAD, FORSYTH, GA 31029 (NAICS 321113). OSHA activity number 339248247.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Southern Forest Industries, INC. — free Get an email when a new federal OSHA severe-injury report for Southern Forest Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3794 OLD MACON ROAD
City
FORSYTH
State
GA
ZIP
31029
Mailing
P.O. BOX 373, SMARR, GA 31086
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321113
Employees
31
Ownership type
A

11 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 20, 2013
Abate by
Jan 17, 2014
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards.  On or about July 31, 2013 at 3794 Old Macon Road, Forsyth, Georgia: Employee accessing the shut off switch on the chip conveyor was exposed to a fall hazard of more than 6-feet to the lower level.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.147 C04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Dec 20, 2013
Abate by
Jan 17, 2014
Penalty
Initial $4,900 · Current $2,100 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section.    On or about July 31, 2013 at 3794 Old Macon Road, Forsyth, Georgia: The employer did not develop Lockout and Tag out procedures for the Block Chipper.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $4900

1910.178 Q01

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 20, 2013
Abate by
Jan 17, 2014
Penalty
Initial $4,200 · Current $1,000 Reduced
29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel.    On or about July 31, 2013 at 3794 Old Macon Road, Forsyth, Georgia: Employees were exposed to struck-by hazards when the hand brake on the Daewoo Power industrial Truck (PIT) did not work. The PIT was not removed from service and the necessary repairs made.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $4200

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 20, 2013
Abate by
Jan 17, 2014
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch.   On or about July 31, 2013 at 3794 Old Macon Road, Forsyth, Georgia: In the maintenance shop, the tongue guards on the bench grinder were not properly aligned. The opening on the stone wheel was 1-1/2". The employees were exposed to a struck by hazard.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.219 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 20, 2013
Abate by
Jan 17, 2014
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft.  On or about July 31, 2013, at 3794 Old Macon Road, Forsyth, Georgia: Employees were exposed to being caught-by a foot long keyed rotating shaft on a conveyor in the saw mill.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.219 C04 II

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 20, 2013
Abate by
Jan 17, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.219(c)(4)(ii): The unused keyway(s) of projecting shaft end(s) were not filled up or covered.   On or about July 31, 2013 at 3794 Old Macon Road, Forsyth, Georgia: Employees are exposed to a caught-by hazard in the saw mill, when the foot long keyed rotating shaft was not filled in or covered.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 E03 II C 3

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 20, 2013
Abate by
Jan 17, 2014
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.253(e)(3)(ii)(C)(3): Flashback protection was not provided by an approved device that would prevent flame from passing into the fuel gas system.  On or about July 31, 2013 at 3794 Old Macon Road, Forsyth, Georgia: The welder was exposed to an explosion hazard when the regulator was not equipped with flashback arrestors.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.303 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 20, 2013
Abate by
Jan 17, 2014
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees.   On or about July 31, 2013 at 3794 Old Macon Road, Forsyth, Georgia: The employees store their welding rods in the refrigerator. In the maintenance shop, the employees are exposed to an electrical hazard when the heat lamp was plugged into a broken 120 volt electrical receptacle.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.305 B02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 20, 2013
Abate by
Jan 17, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy.  On or about July 31, 2013 at 3794 Old Macon Road, Forsyth, Georgia: In the maintenance shop, behind the refrigerator, the faceplate was missing on the receptacle. The employees were exposed to an electrical hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 20, 2013
Abate by
Jan 17, 2014
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed.  On or about July 31, 2013 at 3794 Old Macon Road, Forsyth, Georgia: In the maintenance office, employees have to access the electrical panel to turn on/off lights and various pieces of equipment. In the panel, breakers are missing exposing employees to an electrical shock hazard.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.305 G01 IV A

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 20, 2013
Penalty
Initial $2,100 · Current $1,260 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure.     On or about July 31, 2013 at 3794 Old Macon Road, Forsyth, Georgia: The employees in the maintenance shop were exposed to an electrical hazard when a flexible cord was installed to provide power to the ceiling fan.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2100

View Southern Forest Industries, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339248247.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.