FREER, TX —
OSHA Inspection: STX PROCESS EQUIPMENT LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of STX PROCESS EQUIPMENT LLC in 4819 HWY 44, FREER, TX 78357 (NAICS 332439). OSHA activity number 339263139.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STX PROCESS EQUIPMENT LLC
- Site address
- 4819 HWY 44
- City
- FREER
- State
- TX
- ZIP
- 78357
- Mailing
- 4819 HWY 44, FREER, TX 78357
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332439
- Employees
- 47
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.305 G02 III
- Issued
- Dec 19, 2013
- Abate by
- Jan 21, 2014
- Penalty
- Initial $5,000 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: At this workplace, employees conducted metal fabrication and utilized an electrical welder powered by a flexible cord which had not been provided with strain relief.
Recent events (2)
- — I (S) $3000
- — Z (S) $5000
1910.334 A02 II
- Issued
- Dec 19, 2013
- Abate by
- Jan 21, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service and an employee was using it before repairs and tests necessary to render the equipment safe were made: At this workplace employees conducted metal fabrication production and utilized a 4.5 inch angle grinder with a damaged electrical cord and it was not placed out of service.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L01 I
- Issued
- Dec 19, 2013
- Abate by
- Jan 21, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): At this workplace employees conducted metal fabrication and operated powered industrial trucks without required training and evaluation.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 Q07
- Issued
- Dec 19, 2013
- Abate by
- Jan 21, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service: At this workplace employees conductied metal fabrication production and operated industrial powered trucks without inspecting for serviceability prior to operation.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at STX Process Equipment LLC
View STX Process Equipment LLC's full OSHA safety record →
More inspections in this industry (NAICS 332439)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339263139.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.