On , OSHA opened a planned safety inspection of ADVENT BUILDERS in CONSOLATION SREET, DEDEDO, GU 96929 (NAICS 236115). OSHA activity number 339268054.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADVENT BUILDERS
- Site address
- CONSOLATION SREET
- City
- DEDEDO
- State
- GU
- ZIP
- 96929
- Mailing
- P.O. BOX 315863, TAMUNING, GU 96913
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 12
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1926.404 B01 I
- Issued
- Nov 6, 2013
- Abate by
- Nov 19, 2013
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. Construction Site, outside perimeter, near electrical panel board - Noted on or about 8/8/13 and at times prior thereto, ground fault circuit interrupter protection or an assured equipment grounding conductor program was not used when a 110 VAC right angle grinder was powered through an extension cord. The system did not trip when tested. Employees were exposed to the hazards of contacting electricity.
Recent events (2)
- · I (S) $1200
- · Z (S) $1200
1926.404 F06
- Issued
- Nov 6, 2013
- Abate by
- Nov 19, 2013
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: Construction Site, outside perimeter, near electrical panel box - Noted on or about 8/8/13 and at times prior thereto, an extension cord used to energize (110 VAC) a right angle grinder, was missing a ground pin.
Recent events (2)
- · I (S) $0
- · Z (S) $1200
1926.1052 C01 II
- Issued
- Nov 6, 2013
- Abate by
- Nov 19, 2013
- Penalty
- Initial $1,600 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: Construction Site, stairs leading to second level - Noted on or about 8/8/13 and at times prior thereto, stairs with 12 risers (36"W, 94.5" fall hazard from top riser to ground) were not equipped with a handrail.
Recent events (2)
- · I (S) $1200
- · Z (S) $1600
1926.51 F01
- Issued
- Nov 6, 2013
- Abate by
- Nov 19, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.51(f)(1): The employer shall provide adequate washing facilities for employees engaged in the application of paints, coating, herbicides, or insecticides, or in other operations where contaminants may be harmful to the employees. Such facilities shall be in near proximity to the worksite and shall be so equipped as to enable employees to remove such substances. Construction Site - Noted on or about 8/8/13 and at times prior thereto, adequate washing facilities were not provided for employees observed applying Behr Ultra Pure White 1750 paint on interior walls on the ground level. Soap and hand towels were not provided. Employees did not wear gloves and were observed with paint on their fingers and hands.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Advent Builders
View Advent Builders's full OSHA safety record →
More inspections in this industry (NAICS 236115)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339268054.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.