CUMBERLAND, RI —
OSHA Inspection: THE OKONITE COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of THE OKONITE COMPANY in 111 MARTIN ST, CUMBERLAND, RI 02864 (NAICS 331422). OSHA activity number 339292450.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THE OKONITE COMPANY
- Site address
- 111 MARTIN ST
- City
- CUMBERLAND
- State
- RI
- ZIP
- 02864
- Mailing
- 111 MARTIN ST, CUMBERLAND, RI 02864
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331422
- Employees
- 104
- Ownership type
- A
Citations
9 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 22, 2013
- Abate by
- Nov 6, 2013
- Penalty
- Initial $3,740 · Current $1,870 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to his employees in that employees were exposed to the hazards of being struck by materials being handled with a hoist being operated with a hook whose latch did not effectively close the hook's throat: (a) Insulating area: The latch on the hook of the Coffing 1/2 ton electric hoist, unit #1, was broken, did not effectively close the throat of the hook, and was not removed from service or moused until the latch was replaced or repaired, on or about 8-13-13. ."
Recent events (2)
- — I (S) $1870
- — Z (S) $3740
1910.22 C
- Issued
- Oct 22, 2013
- Abate by
- Dec 6, 2013
- Penalty
- Initial $4,675 · Current $2,337 Reduced
General-duty citation text
29 CFR 1910.22(c): Covers and/or guardrails were not provided to protect personnel from the hazards of open pits, tanks, vats, ditches, etc.: (a) Testing area: The opening to the large water tank on the front side of the tank was not protected by an adequate guardrail, on or about 8-13-13.
Recent events (2)
- — I (S) $2337
- — Z (S) $4675
1910.212 A01
- Issued
- Oct 22, 2013
- Abate by
- Dec 6, 2013
- Penalty
- Initial $3,740 · Current $1,870 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s)created by ingoing nip points and/or rotating parts: (a) Insulating area: The ingoing nip point between the two rollers on CLX192 was not guarded by an adequate guard or guarding device, on or about 8-13-13. (b) Machine shop: The portions of the rotating saw blade outside of the guide rolls on the Wells metal band saw were not guarded by an adequate guard or guarding device, on or about 8-13-13.
Recent events (2)
- — I (S) $1870
- — Z (S) $3740
1910.219 C03
- Issued
- Oct 22, 2013
- Abate by
- Jan 6, 2014
- Penalty
- Initial $3,740 · Current $1,870 Reduced
General-duty citation text
29 CFR 1910.219(c)(3): Vertical and inclined shafting seven (7) feet or less from floor or working platform, excepting maintenance runways, shall be enclosed with a stationary casing in accordance with requirements of paragraphs (m) and (o) of this section: (a) Insulating area: The inclined shafting on take up units CLX10 and CLX191 were not enclosed with a stationary casing in accordance with requirements of paragraphs (m) and (o) of this section, on or about 8-13-13.
Recent events (2)
- — I (S) $1870
- — Z (S) $3740
1910.242 B
- Issued
- Oct 22, 2013
- Abate by
- Nov 6, 2013
- Penalty
- Initial $2,384 · Current $1,192 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: (a): Machine shop: The compressed air of the compressed air gun used for cleaning purposes was not reduced to less than 30 p.s.i, on or about 8-13-13.
Recent events (2)
- — I (S) $1192
- — Z (S) $2384
1910.303 B02
- Issued
- Oct 22, 2013
- Abate by
- Nov 6, 2013
- Penalty
- Initial $3,740 · Current $1,870 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) Insulating area I6: The Curtis and Tripp Lite Relocatable Power Taps (power strips) that were in use powering a microscope and two printers were not installed in accordance with instructions from the manufacturer and included in the listing and labeling, UL XBYS, in that they were series connected (daisy chained) to each other, on or about 8-13-13. (b) Insulating area I5: The Rohs Relocatable Power Tap (power strip) that was in use powering a strobe and inspection camera was not installed in accordance with instructions from the manufacturer and included in the listing and labeling, UL 1363, in that is was not directly connected to a permanently installed branch circuit, on or about 8-13-13. (c) CLX workbench: The three Relocatable Power Taps (power strips) that were in use powering a drill press and bandsaw were not installed in accordance with instructions from the manufacturer and included in the listing and labeling, UL 1363, in that they were series connected (daisy chained) to each other, and were not directly connected to a permanently installed branch circuit, on or about 8-13-13.
Recent events (2)
- — I (S) $1870
- — Z (S) $3740
1910.305 G01 IV
- Issued
- Oct 22, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv): (a) Insulating area: The extension cord in use and powering the Clinton HA1677 Spark Tester was used as a substitute for the fixed wiring of the structure, on or about 8-13-13.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 F06 II
- Issued
- Oct 22, 2013
- Abate by
- Nov 6, 2013
- Penalty
- Initial $2,805 · Current $1,403 Reduced
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with the Product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under the hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical: (a) Drop wire area: The lab bottle of Gem Gravure 1000Q, a flammable liquid, was not legibly labeled, tagged or marked to identify the name of the material and any hazard warnings appropriate to the product, on or about 8-13-13.
Recent events (2)
- — I (S) $1403
- — Z (S) $2805
1910.22 D01
- Issued
- Oct 22, 2013
- Abate by
- Nov 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate: (a) Warehouse: The 3 and 4 tier metal storage racks being used to store materials were not marked to indicate the maximum permissible load that can be imposed upon them, on or about 8-13-13.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at The Okonite Company
View The Okonite Company's full OSHA safety record →
More inspections in this industry (NAICS 331422)
More inspections in RI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339292450.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.