Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PTM OF BOISE, LLC DBA VALLEYRIDE

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PTM OF BOISE, LLC DBA VALLEYRIDE in 4788 SOUTH ORCHARD ST., BOISE, ID 83705 (NAICS 485113). OSHA activity number 339292914.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch PTM of Boise, LLC DBA Valleyride — free Get an email when a new federal OSHA severe-injury report for PTM of Boise, LLC DBA Valleyride is published. One employer, no account, unsubscribe in one click.
Site address
4788 SOUTH ORCHARD ST.
City
BOISE
State
ID
ZIP
83705
Mailing
700 NE 2ND ST. STE. 100, MERIDIAN, ID 83642
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
485113
Employees
93
Ownership type
A

10 citations on file for this inspection.

1910.147 C05 II D

Serious Gravity 5 1 instance 6 exposed
Issued
Jan 15, 2014
Abate by
Jan 28, 2014
Penalty
Initial $2,975 · Current $2,975
29 CFR 1910.147(c)(5)(ii)(D): Lockout devices and Tagout devices did not indicate the identity of the employee applying the device(s):  a)      In the shop; On or before August 13, 2013, and at times prior thereto, the employer did not ensure that the tag on the broken garage bay door identified who applied the tag and why it was applied.   Note: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $2975
  • — Z (S) $2975

1910.147 C05 III

Serious Gravity 5 1 instance 6 exposed
Issued
Jan 15, 2014
Abate by
Jan 28, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(5)(iii): Tagout devices utilized did not warn against hazardous conditions if the machine or equipment was energized:  a)      In the shop; On or before August 13, 2013, and at times prior thereto, the employer did not ensure that the tag identified the hazardous condition on the garage bay door.  Note: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I

Serious Gravity 5 2 instances 10 exposed
Issued
Jan 15, 2014
Abate by
Feb 11, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed:   a)      In the Compressed natural Gas pump yard; On or before August 13, 2013, and at times prior thereto, the employer did not conduct any inspections of their energy control procedures for the CNG system.  b)      In the shop; On or before August 13, 2013, and at times prior thereto, the employer did not conduct any inspections of their energy control procedures for the garage door.  Note: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 IV

Serious Gravity 5 1 instance 16 exposed
Issued
Jan 15, 2014
Abate by
Feb 11, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(iv): The employer did not certified that employee training had been accomplished:   a)      In the shop; On or before August 13, 2013, and at times prior thereto, the employer did not /could not certify that all authorized, affected or other employees had been trained on the parent company Lock out tag out energy control program.   Note: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 I

Deleted Serious Gravity 5 2 instances 10 exposed
Issued
Jan 15, 2014
Abate by
Feb 11, 2014
Penalty
Initial $2,975 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    a)      In the Compressed natural gas yard; On or before August 13, 2013, and at time prior thereto, the employer did not develop and implement written specific procedures for the maintenance and repair of the lectro gas dryer.    b)     In the shop; On or before August 13, 2013, and at times prior thereto, the employer did not  implement the "PTM of Boise Hazardous Energy Control program" specifically for the lock out or tag out of the damaged garage door.    Note: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2975

1910.145 C03

Other-than-serious 1 instance 10 exposed
Issued
Jan 15, 2014
Abate by
Feb 11, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.145(c)(3): Safety instruction sign(s) were not used where there was a need for general instructions and suggestions relative to safety measure(s):  a)      In the shop; On or before August 13, 2013, and at times prior thereto, the employer did not install signs for the eye wash station, the fire extinguishers or use of personal protective equipment.    Note: Abatement certification IS required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 P01

Other-than-serious 1 instance 6 exposed
Issued
Jan 15, 2014
Abate by
Feb 11, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s):   a)      In the shop; On or before August 13, 2013, and at times prior thereto, the employer did not establish a work rule requiring employees to perform a pre-use check of the Toyota powered industrial truck prior to their use each day in order to identify problems, such as the leaking relief valve for the Compressed natural gas regulator.  Note: Abatement certification IS required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 A04

Other-than-serious 1 instance 6 exposed
Issued
Jan 15, 2014
Abate by
May 1, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.178(a)(4): Capacity, operation, and maintenance instruction plates, tags or decals of the powered industrial truck were not changed accordingly:  a)      In the shop; On or before August 13, 2013, and at times prior thereto, the employer did not obtain a new data plate for the Toyota powered industrial truck (Model 7FGU26, S/N 64410 Type LP) when they converted it to a compressed natural gas fueled truck.   Note: Abatement certification and documentation ARE required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.244 A02 VI A

Deleted Other-than-serious 2 instances 10 exposed
Issued
Jan 15, 2014
Abate by
Feb 11, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.244(a)(2)(vi)(a): Each jack used constantly or intermittently at a single locality  was not thoroughly inspected at least once every six months:   a)      In the shop; On or before August 13, 2013, and at times prior thereto, the employer did not inspect and document the results of the inspection of the Hetra Wheel lift jacks.  b)       In the shop; On or before August 13, 2013, and at times prior thereto, the employer did not inspect and document the results of the inspection of the Grey Wheel lifts jacks.  Note: Abatement certification IS required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B02 I

Other-than-serious 1 instance 6 exposed
Issued
Jan 15, 2014
Abate by
Jan 28, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:   a)      In the air compressor shed inside the CNG yard; On or before August 13, 2013, and at times prior thereto, the overhead light fixture was missing a base and had exposed energized conductors at 6 feet 6 inches above the floor.  Note: Abatement certification IS required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View PTM of Boise, LLC DBA Valleyride's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339292914.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.