Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ALIN MACHINING COMPANY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ALIN MACHINING COMPANY, INC. in 3131 W. SOFFEL AVENUE, MELROSE PARK, IL 60160 (NAICS 333293). OSHA activity number 339295065.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Alin Machining Company, INC. — free Get an email when a new federal OSHA severe-injury report for Alin Machining Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3131 W. SOFFEL AVENUE
City
MELROSE PARK
State
IL
ZIP
60160
Mailing
3131 W. SOFFEL AVENUE, MELROSE PARK, IL 60160
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333293
Employees
148
Ownership type
A

11 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 27, 2013
Abate by
Nov 15, 2013
Penalty
Initial $3,060 · Current $1,685 Reduced
29 CFR 1910.23(c)(1):  Open sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not provided with a mid rail where required:      a) - The above the Stock Room was not provided with a mid rail along the space.  Employees were exposed to a falling hazard of over 10 feet, when accessing the above storage space.
Recent events (2)
  • — I (S) $1685
  • — Z (S) $3060

1910.36 D01

Serious Gravity 5 1 instance 10 exposed
Issued
Sep 27, 2013
Abate by
Nov 15, 2013
Penalty
Initial $3,060 · Current $1,685 Reduced
29 CFR 1910.36(d)(1): Employees were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:      a) Plant #2 - The exit door was locked from the inside.  The exit opening had a sliding gate across it and locked with a key preventing employees from exiting the building during an emergency.
Recent events (2)
  • — I (S) $1685
  • — Z (S) $3060

1910.147 C04 I

Serious Gravity 5 1 instance 7 exposed
Issued
Sep 27, 2013
Abate by
Nov 27, 2013
Penalty
Initial $3,825 · Current $2,100 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in the activities covered by this section:        a) The employer did not develop, document, and utilize energy control procedures, when performing servicing or maintenance on the Matsuura RA-4G, and NAAS VF#5 CM-02 CNC machines, and the Amada horizontal saws.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3825

1910.147 C06 I

Serious Gravity 5 1 instance 7 exposed
Issued
Sep 27, 2013
Abate by
Nov 27, 2013
Penalty
Initial $3,825 · Current $2,100 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedures and the requirements of this standard are being followed:       a) The employer did not conduct periodic inspections of their energy control procedures to ensure that the procedures and the requirements of their energy control program were being followed by employees.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3825

1910.178 A06

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 27, 2013
Abate by
Nov 15, 2013
Penalty
Initial $3,060 · Current $1,685 Reduced
29 CFR 1910.178(a)(6): The user did not ensure that all nameplates and markings are in place and are maintained in a legible condition.    a) The employer failed to ensure that the Toyota powered industrial truck was with a nameplate and markings.
Recent events (2)
  • — I (S) $1685
  • — Z (S) $3060

1910.179 G01 V

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 27, 2013
Abate by
Nov 15, 2013
Penalty
Initial $3,060 · Current $1,685 Reduced
29 CFR 1910.179(g)(1)(v): Pendant control boxes shall be constructed to prevent electrical shock and shall be clearly marked for identification of functions:    a) Raw Material Handling Area - The Hydro seven ton crane had a pendant control box that did not have the function buttons properly marked for their purpose.
Recent events (2)
  • — I (S) $1685
  • — Z (S) $3060

1910.212 A01

Serious Gravity 5 2 instances 4 exposed
Issued
Sep 27, 2013
Abate by
Nov 15, 2013
Penalty
Initial $3,825 · Current $2,100 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding were not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:      a) Tool Room - The TUR-630A lathe, was not equipped with an enclosure guard for the rotating chuck and chip guard to contain flying chips or sparks.    b) Production Area - The employer had a Amada horizontal metal cutting band saw #BS-02, model #HFA-400W, that did not have the unused portion of the blade guarded on the left hand side facing the saw.    c) Machine Shop Area - The employer had an Amada #BS-04, horizontal metal cutting band saw, that did not have the unused portion of the blade guarded on the left hand side facing the saw.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3825

1910.242 B

Serious Gravity 5 2 instances 5 exposed
Issued
Sep 27, 2013
Abate by
Nov 15, 2013
Penalty
Initial $3,060 · Current $1,685 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:        a) Maintenance Department - The compressed air line nozzle used for cleaning machinery and tooling was operated at over 30 p.s.i.
Recent events (2)
  • — I (S) $1685
  • — Z (S) $3060

1910.305 J01 II

Serious Gravity 1 1 instance 4 exposed
Issued
Sep 27, 2013
Abate by
Nov 15, 2013
Penalty
Initial $2,295 · Current $1,275 Reduced
29 CFR 1910.305(j)(1)(ii): Portable hand-lamps supplied through flexible cords were not equipped with a handle of molded composition or other material approved for the purpose, and a substantial guard attached to the lamp-holder or the handle:          a) Machine Shop - A portable hand lamp with a metal shell, non-insulated handles, and without a guard was clamped on the edge of a CNC machine.  The cord entry on the portable hand lamps had no bushing thereby possibly allowing cable abrasion to occur which would expose live conductors.
Recent events (2)
  • — I (S) $1275
  • — Z (S) $2295

1910.22 D01

Other-than-serious 1 instance 5 exposed
Issued
Sep 27, 2013
Abate by
Nov 15, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.22(d)(1):  In every building or other structure, or part thereof, used for mercantile, business, industrial, or storage purposes, the loads approved by the building official were not marked on plates of approved design, supplied and securely affixed by the owner of the building, or his duly authorized agent, in a conspicuous place in each space to which they related:       a) In the stock room where the top of it was used to store boxes and other equipment and supplies and it did not have a load rating.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.334 A02 I

Other-than-serious 2 instances 4 exposed
Issued
Sep 27, 2013
Abate by
Nov 15, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):          a) Shipping Department - There was an electrical extension cord powering a Ryobi circular saw that had its outer sheath damaged.       a) Machine Shop Plant #2 - There was an electrical extension cord powering a circular fan that had its outer sheath damaged.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Alin Machining Company, INC.'s full OSHA safety record →