CAROL STREAM, IL —
OSHA Inspection: AMERICAN POWER EQUIPMENT, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of AMERICAN POWER EQUIPMENT, INC. in 1370 W ARMY TRAIL ROAD, CAROL STREAM, IL 60188 (NAICS 444210). OSHA activity number 339295099.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMERICAN POWER EQUIPMENT, INC.
- Site address
- 1370 W ARMY TRAIL ROAD
- City
- CAROL STREAM
- State
- IL
- ZIP
- 60188
- Mailing
- 1370 W ARMY TRAIL ROAD, CAROL STREAM, IL 60188
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 444210
- Employees
- 9
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.178 L02 II
- Issued
- Jan 31, 2014
- Abate by
- Mar 7, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(2)(ii): The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace. The employer did not ensure that each powered industrial operator had received training and a performance evaluation (driving test). Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
- — Z (S) $0
1910.303 B02
- Issued
- Jan 31, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: Repair Shop Area. Relocatable power taps (electrical power strips), which were not designed for use in industrial environments, were mounted on the walls and used to power the following equipment: a) A microwave on an extension cord b) An extension cord used for testing snow blower starters c) A time clock on an extension cord. There is no abatement certification or documentation required for this item.
Recent events (1)
- — Z (S) $0
1910.305 G01 IV D
- Issued
- Jan 31, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were used where attached to building surfaces: Repair Shop Area. A flexible cord (110v) used as an extension cord for a microwave, was affixed to a wall and plugged into a relocatable power tap mounted to the wall. There is no abatement certification or documentation required for this item.
Recent events (1)
- — Z (S) $0
1910.37 A03
- Issued
- Jan 31, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(3): Exit routes were not free and/or unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. An exit route to the exit door at the back of the warehouse was temporarily obstructed by materials stored on pallets and empty cardboard boxes. There is no abatement documentation or certification required for this item.
Recent events (1)
- — Z (O) $0
1910.1200 E01
- Issued
- Jan 31, 2014
- Abate by
- Mar 7, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: The employer, American Power Equipment, Inc., did not develop, implement, and maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: In the repair area, chemicals such as but not limited to carburetor cleaner, touch-up spray paints and solvents, are used by employees as part of regular operations. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c)
Recent events (1)