Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MORGAN ROOFING

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MORGAN ROOFING in 402 OLD PALTZER CT, APPLETON, WI 54913 (NAICS 238160). OSHA activity number 339296675.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Morgan Roofing — free Get an email when a new federal OSHA severe-injury report for Morgan Roofing is published. One employer, no account, unsubscribe in one click.
Establishment
MORGAN ROOFING
Site address
402 OLD PALTZER CT
City
APPLETON
State
WI
ZIP
54913
Mailing
PO BOX 221, HUSTISFORD, WI 53034
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
A

5 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 3, 2013
Abate by
Oct 23, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents.    a)  On 08-14-13, employees who were installing shingles were using pneumatic nail guns without eye protection.     ABATEMENT CERTIFICATION REQUIIRED
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.501 B13

Serious Gravity 5 2 instances 2 exposed
Issued
Sep 3, 2013
Abate by
Oct 23, 2013
Penalty
Initial $2,000 · Current $1,800 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):     a)  On 08-14-13, employees were installing shingles on a house second story 10:12 pitch roof with an eave edge seventeen (17) feet above compacted surface without fall protection equipment.    b)  On 08-14-13, employees were installing shingles on a garage 10:12 pitch roof with an eave edge nine and one half (9.5) feet above compacted surface without fall protection equipment.    ABATEMENT CERTIFICATION REQUIIRED
Recent events (2)
  • — I (S) $1800
  • — Z (S) $2000

1926.503 A02 VIII

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 3, 2013
Abate by
Oct 23, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(2)(viii): The employer did not assure that each employee had been trained by a competent person qualified in the standards contained in subpart M:  a)  On or before, the employer did not provide employee fall protection safety training for employees who were working on a 10:12 pitch roof with an eave edge seventeen (17) feet above compacted surfaces without fall protection equipment; employees were using slide boards as fall protection.  ABATEMENT CERTIFICATION REQUIIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B09

Other-than-serious 1 instance 2 exposed
Issued
Sep 3, 2013
Abate by
Oct 23, 2013
Penalty
Initial $1,200 · Current $0 Reduced
29 CFR 1926.1053(b)(9): The area around the top and/or bottom of (a) ladder(s) was not kept clear:      a)  On 08-14-13, employees who were accessing a roof work surface were utilizing a 28 ft. extension ladder with a bundle of shingles placed on the base of the ladder.    ABATEMENT CERTIFICATION REQUIIRED
Recent events (2)
  • — I (O) $0
  • — Z (S) $1200

1926.1060 A01 V

Other-than-serious 2 instances 2 exposed
Issued
Sep 3, 2013
Abate by
Oct 23, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.1060(a)(1)(v): The employer did not ensure that each employee using ladders and stairways had been trained by a competent person in the standards contained in Subpart X:    a)  On 08-14-13, employees were using extension ladders at the site to access the roof and work from and had not received training.  Materials were laid at the base of one ladder creating a tripping hazard.    ABATEMENT CERTIFICATION REQUIIRED
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

View Morgan Roofing's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339296675.