Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MORGAN ROOFING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MORGAN ROOFING in 124 GENESEE ST., DELAFIELD, WI 53018 (NAICS 238160). OSHA activity number 346774334.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Morgan Roofing — free Get an email when a new federal OSHA severe-injury report for Morgan Roofing is published. One employer, no account, unsubscribe in one click.
Establishment
MORGAN ROOFING
Site address
124 GENESEE ST.
City
DELAFIELD
State
WI
ZIP
53018
Mailing
N56 W35648 LISBON RD, OCONOMOWOC, WI 53066
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.501 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 21, 2023
Penalty
Initial $4,688 · Current $2,344 Reduced
29 CFR  1926.501(b)(1): Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  (a) On or about June 15, 2023, at the jobsite located at 124 Genesee Street Delafield, WI 53018, employees engaged in roofing work of a new dental office were not protected from falling to the ground below. This exposed employees to a fall hazard of approximately 13 feet.
Recent events (2)
  • — I (S) $2344
  • — Z (S) $4688

1926.1053 B01

Serious Gravity 5 2 instances 2 exposed
Issued
Jul 21, 2023
Penalty
Initial $3,349 · Current $1,674 Reduced
29 CFR  1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.  (a) On or about June 15, 2023, at the jobsite located at 124 Genesee Street Delafield, WI 53018, the ladder employees used to access the roof of a new dental office being built, did not extend three feet above the landing surface, exposing the employees to a fall hazard of approximately 13 feet.
Recent events (2)
  • — I (S) $1674
  • — Z (S) $3349

View Morgan Roofing's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346774334.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.