Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: USDA, ANIMAL AND PLANT HEALTH INSPECTION SERVICE/ PLANT PROTECTION QUARANTINE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of USDA, ANIMAL AND PLANT HEALTH INSPECTION SERVICE/ PLANT PROTECTION QUARANTINE in 8775 TECHNOLOGY WAY, RENO, NV 89521 (NAICS 813312). OSHA activity number 339298713.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Usda, Animal and Plant Health Inspection Service/ Plant Protection Quarantine — free Get an email when a new federal OSHA severe-injury report for Usda, Animal and Plant Health Inspection Service/ Plant Protection Quarantine is published. One employer, no account, unsubscribe in one click.
Site address
8775 TECHNOLOGY WAY
City
RENO
State
NV
ZIP
89521
Mailing
8775 TECHNOLOGY WAY, RENO, NV 89521
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
813312
Employees
100
Ownership type
D

9 citations on file for this inspection.

1910.36 G02

Serious Gravity 1 2 instances 2 exposed
Issued
Sep 23, 2013
Abate by
Oct 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points.  (a) On or about August 5, 2013, in the staff and wildlife biologists' office spaces, exit/egress were 19 and 25 inches obstructed by boxes, desk, file cabinet and furniture.
Recent events (1)
  • — Z (S) $0

1910.157 C01

Serious Gravity 5 2 instances 3 exposed
Issued
Sep 23, 2013
Abate by
Oct 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries.  (a) On or about August 5, 2013, in the Archive and Break room, portable fire extinguishers were free standing on tables and floor.
Recent events (1)
  • — Z (S) $0

1910.253 B04 III

Serious Gravity 1 1 instance 4 exposed
Issued
Sep 23, 2013
Abate by
Oct 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.  (a) On or about August 5, 2013, in the warehouse, oxygen and acetylene gas cylinders were stored together.
Recent events (1)
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 23, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling.  (a) On or about August 5, 2013, in the PPQ Lab, two re-locatable power taps were daisy chained together.
Recent events (1)
  • — Z (S) $0

1910.303 F02

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 23, 2013
Abate by
Oct 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident.  (a) On or about August 5, 2013, in the electrical room, the P2 power panel circuit breakers were not labled.
Recent events (1)
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 23, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A):   Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure.  (a) On or about August 5, 2013, in the PPQ area, a white extension cord was used to extend power to the Holmes oscillating pedestal fan and a surge protector for more than 90 days.
Recent events (1)
  • — Z (S) $0

1910.1200 E01 I

Serious Gravity 1 1 instance 7 exposed
Issued
Sep 23, 2013
Abate by
Oct 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1)(i):  The employer did not comply a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet.  (a) On or about August 5, 2013, in the mini shop area, the employer did not have a complete inventory sheet for all the chemicals present in the work place such as great value bleach, staticide spray nine, grease lightning, etc,.
Recent events (1)
  • — Z (S) $0

1910.1200 G01

Serious Gravity 1 1 instance 7 exposed
Issued
Sep 23, 2013
Abate by
Oct 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use:  (a) On or about 3/28/13, in the mini shop area,  material safety data sheets were not available for chemicals present in the workplace such as great value bleach, staticide spray nine, grease lightning, etc.,.
Recent events (1)
  • — Z (S) $0

1910.304 F01 IV

Other-than-serious 1 instance 2 exposed
Issued
Sep 23, 2013
Abate by
Oct 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel.  (a) On or about August 5, 2013, the power panels in the electrical room area were obstructed by chair, plant materials, boxes, etc.,.
Recent events (1)
  • — Z (O) $0

View Usda, Animal and Plant Health Inspection Service/ Plant Protection Quarantine's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339298713.