Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RAM PLASTICS CO.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of RAM PLASTICS CO. in 11401 SOUTH AVENUE EXTENSION, P.O. BOX 402, NORTH LIMA, OH 44452 (NAICS 326199). OSHA activity number 339302010.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch RAM Plastics CO. — free Get an email when a new federal OSHA severe-injury report for RAM Plastics CO. is published. One employer, no account, unsubscribe in one click.
Establishment
RAM PLASTICS CO.
Site address
11401 SOUTH AVENUE EXTENSION, P.O. BOX 402
City
NORTH LIMA
State
OH
ZIP
44452
Mailing
PO BOX 402, NORTH LIMA, OH 44452
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
45
Ownership type
A

5 citations on file for this inspection.

1910.242 B

Other-than-serious 1 instance 43 exposed
Issued
Nov 5, 2013
Abate by
Nov 23, 2013
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    On or about August 15, 2013, compressed air used for cleaning purposes was found to have a nozzle end pressure above 30 psi.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3500

1910.305 G01 IV A

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 5, 2013
Abate by
Nov 23, 2013
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:     On or about August 15, 2013, a flexible cord in the maintenance area was used as a substitute for the fixed wiring of a structure in that it was plugged into an electrical outlet, zip tied to conduit running along the wall, and wired directly into an outlet box used to power grinding equipment.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.305 G01 IV D

Serious Gravity 5 1 instance 40 exposed
Issued
Nov 5, 2013
Abate by
Nov 23, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords were attached to building surfaces:  On or about August 15, 2013, a flexible cord in the maintenance area was used as a substitute for the fixed wiring of a structure in that it was plugged into an electrical outlet, zip tied to conduit running along the wall, and wired directly into an outlet box used to power grinding equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 5, 2013
Abate by
Nov 23, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:   On or about August 15, 2013, strain relief was not used on a flexible cord wired into an electrical outlet box in the maintenance area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.95 G06

Repeat Gravity 5 1 instance 43 exposed
Issued
Nov 5, 2013
Penalty
Initial $7,000 · Current $4,200 Reduced

Hazardous substances 8111

29 CFR 1910.95(g)(6): At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels :     a. An employee operating press #12 was exposed to noise on or about October 30, 2013. The employee had a time weighted average of 89.5 dBA and a dose of 93.72%, which is above the action level for hearing conservation program implementation. The total sampling time was 463 minutes, with the remaining 17 minutes considered as zero exposure.       b. An employee operating press #3 was exposed to noise on or about October 30, 2013. The employee had a time weighted average of 89.7 dBA and a dose of 96.24%, which is above the action level for hearing conservation program implementation. The total sampling time was 461 minutes, with the remaining 19 minutes considered as zero exposure.    On or about August 15, 2013, audiograms were not provided on an annual basis for employees exposed to noise above the action level.     RAM Plastics Co was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.95(g)(5)(i), which was contained in OSHA inspection number 110726, citation number 1, item number 2b and was affirmed as a final order on February 16, 2012, with respect to a workplace located at 11401 South Avenue, North Lima, OH 44452.
Recent events (2)
  • — I (R) $4200
  • — Z (R) $7000

View RAM Plastics CO.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339302010.