PALMETTO, GA —
OSHA Inspection: SPURLIN INDUSTRIES, INC.
Follow-up inspection · Health discipline
At a glance
On , OSHA opened a follow-up health inspection of SPURLIN INDUSTRIES, INC. in 625 MAIN STREET, PALMETTO, GA 30268 (NAICS 326191). OSHA activity number 339351876.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SPURLIN INDUSTRIES, INC.
- Site address
- 625 MAIN STREET
- City
- PALMETTO
- State
- GA
- ZIP
- 30268
- Mailing
- 625 MAIN STREET, PALMETTO, GA 30268
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326191
- Employees
- 36
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.95 C01
- Issued
- Nov 6, 2013
- Penalty
- Initial $7,000 · Current $4,200 Reduced
General-duty citation text
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: a) Grinding/cutting area- The employer failed to implement a hearing conservation program for an employee grinding and cutting flanges off of fiberglass tubs and showers. The employee was exposed to continuous noise at 132% of the permissible daily exposure of 85 bBA (8-hour time weighted average) or an equivalent sound level of 98.5 dBA, which exceeded the action limit of 85 dBA. Results were from a 378 minute sampling period conducted on August 29, 2013. Spurlin Industries Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 601958, citation number 1, item number 1 and was affirmed as a final order on January 29, 2013 with respect to a workplace located at 625 Main Street, Palmetto, Georgia.
Recent events (2)
- — I (R) $4200
- — Z (R) $7000
1910.134 C02 I
- Issued
- Nov 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: Throughout the facility - An appendix D of the respiratory protection standard was not provided for employees voluntarily using a two strap filtering face piece.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Spurlin Industries, INC.