OSHA Inspection: JOHN ANDERSON CONSTRUCTION, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of JOHN ANDERSON CONSTRUCTION, INC. in LEASED ROAD OFF OF EAST 5TH AVENUE, WARREN, PA 16365 (NAICS 237120). OSHA activity number 339357105.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch John Anderson Construction, INC. — free Get an email when a new federal OSHA severe-injury report for John Anderson Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
LEASED ROAD OFF OF EAST 5TH AVENUE
City
WARREN
State
PA
ZIP
16365
Mailing
324 PENNSYLVANIA AVENUE WEST, WARREN, PA 16365
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237120
Employees
8
Ownership type
A

4 citations on file for this inspection.

1910.134 C01

Other-than-serious 1 instance 1 exposed
Issued
Dec 11, 2013
Abate by
Jan 30, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:      a.)    John Anderson Construction, Inc., Leased Road off of East 5th Avenue, Warren Pa, 16365-on or about August 21st, 2013, and times prior thereto:  Company employees were required to wear filter facepiece respirators (3M and/or MSA Combo Classic brand half mask respirators with P100 multi-gas cartridges) during cutting operations of old gas line pipe.  The Company had not developed and maintained a written Respiratory Protection Program.
Recent events (1)
  • — Z (O) $0

1910.134 E01

Other-than-serious 1 instance 1 exposed
Issued
Dec 11, 2013
Abate by
Jan 30, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:    a.)John Anderson Construction, Inc., Leased Road off of East 5th Avenue, Warren Pa, 16365-on or about August 21st, 2013, and times prior thereto:  Company employees were required to wear filter facepiece respirators (3M and/or MSA Combo Classic brand half mask respirators with P100 multi-gas cartridges) during cutting operations of old gas line pipe.  Company employees were not provided with medical evaluations prior to the use of the half mask filtering facepiece respirators.
Recent events (1)
  • — Z (O) $0

1910.134 F02

Other-than-serious 1 instance 1 exposed
Issued
Dec 11, 2013
Abate by
Jan 30, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:     a.)    John Anderson Construction, Inc., Leased Road off of East 5th Avenue, Warren Pa, 16365-on or about August 21st, 2013, and times prior thereto:  Company employees were required to wear filter facepiece respirators (3M and/or MSA Combo Classic brand half mask respirators with P100 multi-gas cartridges) during cutting operations of old gas line pipe.  A company employee was not provided with a fit test prior to the use of a half mask tight-fitting air purifying respirators.
Recent events (1)
  • — Z (O) $0

1910.1200 H03 II

Other-than-serious 1 instance 1 exposed
Issued
Dec 11, 2013
Abate by
Jan 8, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(3)(ii): Employee training did not include the physical and health hazards of the chemicals in the work area:         a.)    John Anderson Construction, Inc., Leased Road off of East 5th Avenue, Warren Pa, 16365-on or about August 21st, 2013, and times prior thereto:  Company employees were working with diesel fuel during fueling operations of the companys excavator. Company employees were not provided with training on the physical and health hazards of the diesel fuel.
Recent events (1)
  • — Z (O) $0

View John Anderson Construction, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339357105.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.