Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,192,068Inspections Most recent open 2026-08-04 Last loaded 2026-08-07

OSHA Inspection: PROSERV CRANE GROUP

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of PROSERV CRANE GROUP in 2020 EAST GRAUWYLER ST., IRVING, TX 75061 (NAICS 333923). OSHA activity number 339361040.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Proserv Crane Group for free Get an email when a new federal OSHA severe-injury report for Proserv Crane Group is published. One employer, no account, unsubscribe in one click.
Establishment
PROSERV CRANE GROUP
Site address
2020 EAST GRAUWYLER ST.
City
IRVING
State
TX
ZIP
75061
Mailing
2020 EAST GRAUWYLER ST., IRVING, TX 75061
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333923
Employees
40
Ownership type
A

8 citations on file for this inspection.

1910.107 B05 I

Serious Gravity 10 2 instances 2 exposed
Issued
Feb 19, 2014
Abate by
Mar 3, 2014
Penalty
Initial $6,300 · Current $2,205 Reduced
CFR 29 1910.107(b)(5)(i): The spraying operations were not designed, installed and maintained so that the average air velocity over the open face of the booth was not less than 100 linear feet per minute. Visible gauges or audible alarm or pressure activated devices were not installed to indicate or insure that the required air velocity was maintained.     This violation most recently occurred on or about August 27, 2013, where employees were exposed to fire hazards because the employers did not ensure spray booth systems effectiveness in controlling airborne hazards and having visible gauges or alarms to ensure air velocity was maintained.
Recent events (2)
  • · I (S) $2205
  • · Z (S) $6300

1910.107 D02

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 19, 2014
Penalty
Initial $0 · Current $0
CFR 29 1910.107(d)(2): All spraying areas were not provided with mechanical ventilation adequate to remove flammable vapors, mists, or powders to a safe location and to confine and control combustible residues so that life was not endangered. Mechanical ventilation was not  kept in operation at all times while spraying operations were being conducted and for a sufficient time thereafter to allow vapors from drying coated articles and drying finishing material residue to be exhausted.  This violation most recently occurred on or about August 27, 2013, where employer did not ensure that mechanical ventilation was kept in operation or in a condition to operate.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.107 B05 IV

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 19, 2014
Abate by
May 30, 2014
Penalty
Initial $6,300 · Current $2,205 Reduced
CFR 29 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers.    This violation most recently occurred on or about August 27, 2013, where the employer did not ensure that the downstream and upstream sides of filters were protected with approved automatic sprinklers.
Recent events (2)
  • · I (S) $2205
  • · Z (S) $6300

1910.107 B09

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 19, 2014
Abate by
Feb 26, 2014
Penalty
Initial $6,300 · Current $2,205 Reduced
29 CFR 1910.107(b)(9): Spray booths were not so installed that all portions were readily accessible for cleaning. A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction.     This violation most recently occurred on or about August 27, 2013, where the employer did not ensure a clear space of not less than 3 feet on all sides of the paint booth was kept free from storage or combustible construction making it accessible for cleaning.
Recent events (2)
  • · I (S) $2205
  • · Z (S) $6300

1910.107 E02

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 19, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.107(e)(2): The quantity of flammable liquids kept in the vicinity of spraying operations was not at the minimum required for operations and exceeded a supply for 1 day or one shift.   This violation most recently occurred on or about August 27, 2013, where two (2) employees were exposed to fire hazards because the quantity of flammable liquids kept in the vicinity of spraying operations was not at the minimum required for operations and exceeded a supply for 1 day or one shift.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.107 G02

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 19, 2014
Abate by
Feb 27, 2014
Penalty
Initial $6,300 · Current $2,205 Reduced
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary.      This violation most recently occurred on or about August 27, 2013, where the employer did not ensure that the walls of the paint booth were kept free from the accumulation of deposits of combustible residues.
Recent events (2)
  • · I (S) $2205
  • · Z (S) $6300

1910.134 C01

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 19, 2014
Abate by
Mar 3, 2014
Penalty
Initial $6,300 · Current $2,205 Reduced
29 CFR 1910.134(c)(1): In the paint booth area, where respirators are necessary to protect the health of the employee and respirators are required by the employer, the employer did not establish and implement a written respiratory protection program with worksite-specific procedures.  The employer did not include in the program the following provisions of this section, 1910.134(c), as applicable.    This violation most recently occurred on or about, August 27, 2013, where employees were exposed to respiratory hazards because the employer did not establish and implement a written respiratory protection program with worksite-specific procedures.  The employer did not include in the program the following provisions of section 1910.134(c).
Recent events (2)
  • · I (S) $2205
  • · Z (S) $6300

1910.157 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 19, 2014
Abate by
Feb 27, 2014
Penalty
Initial $4,500 · Current $1,575 Reduced
29 CFR 1910.157(c)(1): The employer failed to mount portable fire extinguishers so that they were readily accessible to employees without subjecting the employees to possible injury.    This violation occurred on or about, August 27, 2013, where the employer did not ensure that fire extinguishers were mounted to provide easy accessibility to employees.
Recent events (2)
  • · I (S) $1575
  • · Z (S) $4500

View Proserv Crane Group's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339361040.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.