Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THUNDERBOLT MARINE, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of THUNDERBOLT MARINE, INC. in 3124 RIVER DR, SAVANNAH, GA 31404 (NAICS 336611). OSHA activity number 339362592.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Thunderbolt Marine, INC. — free Get an email when a new federal OSHA severe-injury report for Thunderbolt Marine, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3124 RIVER DR
City
SAVANNAH
State
GA
ZIP
31404
Mailing
3124 RIVER DR, SAVANNAH, GA 31404
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336611
Employees
79
Ownership type
A

8 citations on file for this inspection.

1910.106 B02 VII A

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Feb 21, 2014
Abate by
Apr 9, 2014
Penalty
Initial $2,380 · Current $0 Reduced
29 CFR 1910.106(b)(2)(vii)(a): Area(s) surrounding tank(s) containing flammable liquids were not provided with adequate drainage or dikes:    a) At the diesel dispensing station behind the covered work bays, on or about and at times prior to August 27, 2013, the above ground diesel tank that was used to refill forklifts and cranes was not diked, exposing employees to a fire hazard.    ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2380

1910.106 D07 I

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 21, 2014
Abate by
Apr 9, 2014
Penalty
Initial $0 · Current $1,000
29 CFR 1910.106(d)(7)(i): 1910.106(d)(7)(i)  Suitable fire control devices, such as small hose or portable fire extinguishers, were not available at locations where flammable or combustible liquids were stored.    a) At the diesel dispensing station behind the covered work bays, on or about and at times prior to August 27, 2013, the employer did not provide a fire extinguisher at the above ground diesel tank that was used to refill forklifts and cranes, exposing employees to a fire hazard.    ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $0

1910.212 B

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 21, 2014
Penalty
Initial $2,023 · Current $825 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:    a) At the Hydraulics Shop, on or about February 14, 2013 and at times prior to, the employer did not ensure that the drill press was anchored to the work bench, exposing employees to struck-by hazard.    ABATEMENT CERTIFICATION IS NOT REQUIRED.
Recent events (2)
  • — I (S) $825
  • — Z (S) $2023

1910.303 B02

Serious Gravity 1 2 instances 1 exposed
Issued
Feb 21, 2014
Abate by
Apr 9, 2014
Penalty
Initial $1,785 · Current $825 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a) At the Machine Shop, on or about and at times prior to, February 14, 2014, a metal quad receptacle outlet/utility box was mounted on the end of an extension cord, exposing employees to electrical shock and burn hazards.      b) At the Machine Shop, on or about and at times prior to, February 14, 2014, a relocatable power tap (power strip) that was connected to a an extension cord and mounted on the wall was used to provide power for a radio and a battery charger, exposing employees to electrical shock and burn hazards.     ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
  • — I (S) $825
  • — Z (S) $1785

1910.305 G01 IV A

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Feb 21, 2014
Abate by
Mar 19, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a) At Machine Shop, on or about and at times prior to August 27, 2013, an extension cord was used to power a grinder and other power hand tools in lieu of using fixed wiring of a structure, exposing employees to an electrical hazard.   ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C01

Other-than-serious 1 instance 3 exposed
Issued
Feb 21, 2014
Abate by
Apr 9, 2014
Penalty
Initial $595 · Current $350 Reduced

Hazardous substances 0530056020372590

29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:    a) At the facility, on or about and at times prior to August 27, 2013, the employer did not fully document their written Respiratory Protection Program for employees that were required to wear tight fitting respirators, including half mask and full face respirators during sanding, painting, and welding operations, exposing employees to respiratory hazards.       ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
  • — I (O) $350
  • — Z (O) $595

1910.134 D01 III

Other-than-serious 1 instance 3 exposed
Issued
Feb 21, 2014
Abate by
Apr 9, 2014
Penalty
Initial $0 · Current $350

Hazardous substances 0530056020372590

29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminantant's chemical state and physical form:    a) At the facility, on or about and at times prior to August 27, 2013, the employer did not evaluate the exposure levels for employees that were required to wear tight fitting respirators, including half mask and full face respirators during sanding, painting, and welding operations, resulting in a respiratory hazard.     ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
  • — I (O) $350
  • — Z (O) $0

1910.134 G01 I A

Other-than-serious 1 instance 1 exposed
Issued
Feb 21, 2014
Abate by
Apr 9, 2014
Penalty
Initial $0 · Current $350

Hazardous substances 0530056020372590

29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function:    a) At the facility, on or about and at times prior to August 27, 2013, the employer permitted an employee with facial hair (more than one days growth) to wear tight-fitting face piece respirators during painting, sanding, grinding operations, exposing the employee to respiratory and skin irritations.     ABATEMENT CERTIFICATION IS REQUIRED.