OSHA Inspection: AMERICAN MADE SHUTTERS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AMERICAN MADE SHUTTERS, INC. in 203 CHESTERA DRIVE, DAHLONEGA, GA 30533 (NAICS 321911). OSHA activity number 339362600.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch American Made Shutters, INC. — free Get an email when a new federal OSHA severe-injury report for American Made Shutters, INC. is published. One employer, no account, unsubscribe in one click.
Site address
203 CHESTERA DRIVE
City
DAHLONEGA
State
GA
ZIP
30533
Mailing
203 CHESTERRA DRIVE, DAHLONEGA, GA 30533
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321911
Employees
127
Ownership type
A

2 citations on file for this inspection.

1910.107 C06

Serious Gravity 10 1 instance 8 exposed
Issued
Jan 17, 2014
Abate by
Apr 1, 2014
Penalty
Initial $6,300 · Current $3,150 Reduced
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations:    On or about August 15, 2013:    (a) Employees were exposed to fire and explosion hazards while working within twenty (20) feet of spraying operations that included flammable or combustible material to include Albatek BR-1060. Equipment and wiring to include fans, lights and electrical outlets within twenty feet of spraying operation were not explosion - proof approved for the area.
Recent events (2)
  • — I (S) $3150
  • — Z (S) $6300

1910.242 B

Serious Gravity 5 6 instances 7 exposed
Issued
Jan 17, 2014
Abate by
Feb 13, 2014
Penalty
Initial $4,500 · Current $2,250 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i    On or about August 15, 2013:    (a) Employees were exposed to struck by hazards, while utilizing compressed air for cleaning. six air nozzles within the painting area did not have effective chip guarding in place, with pressures measuring between 60 and 85 psi.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $4500

View American Made Shutters, INC.'s full OSHA safety record →