WOODCLIFF LAKE, NJ —
OSHA Inspection: EAST COAST WALL COATINGS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of EAST COAST WALL COATINGS, INC. in 364 CHESTNUT ROAD, WOODCLIFF LAKE, NJ 07677 (NAICS 238140). OSHA activity number 339364150.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EAST COAST WALL COATINGS, INC.
- Site address
- 364 CHESTNUT ROAD
- City
- WOODCLIFF LAKE
- State
- NJ
- ZIP
- 07677
- Mailing
- 352 FRANKLIN AVE, FRANKLIN SQUARE, NY 11010
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 12
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.404 F06
- Issued
- Nov 19, 2013
- Abate by
- Dec 9, 2013
- Penalty
- Initial $1,600 · Current $640 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) On the tubular welded scaffold- Employees were using a heat gun that was powered by an extension cord that was missing a ground pin; on or about 06/12/13.
Recent events (2)
- — I (S) $640
- — Z (S) $1600
1926.405 G02 III
- Issued
- Nov 19, 2013
- Abate by
- Dec 9, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap: a) 1st floor of house- Employee was using a heat gun saw with a spliced cord; on or about 6/12/13.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 B01
- Issued
- Nov 19, 2013
- Abate by
- Dec 9, 2013
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a) On tubular welded scaffold- Employees were exposed to a fall of approximately 20 feet while working on a tubular welded scaffold that was not fully planked; on or about 6/12/13.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1926.451 G01
- Issued
- Nov 19, 2013
- Abate by
- Dec 9, 2013
- Penalty
- Initial $2,800 · Current $1,120 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. a) On tubular welded scaffold- Employee was exposed to a fall of approximately 20 ft while working on a tubular welded scaffold without the use of a fall protection system; on or about 6/12/13.
Recent events (2)
- — I (S) $1120
- — Z (S) $2800
1926.451 H02
- Issued
- Nov 19, 2013
- Abate by
- Dec 9, 2013
- Penalty
- Initial $1,600 · Current $640 Reduced
General-duty citation text
29 CFR 1926.451(h)(2): Employees working below a scaffold were not protected from falling tools, materials or equipment in accordance with the provisions of paragraphs (h)(2)(i)-(v) of this section: a) On tubular welded scaffold- An employee was exposed to an injury while walking under the scaffold that was missing toe boards; on about 6/12/13.
Recent events (2)
- — I (S) $640
- — Z (S) $1600
1926.1053 B01
- Issued
- Nov 19, 2013
- Abate by
- Dec 9, 2013
- Penalty
- Initial $2,000 · Current $800 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. On the tubular welded scaffold- Employees were accessing a ladder that did not extend 3 feet over the landing; on or about 06/12/13.
Recent events (2)
- — I (S) $800
- — Z (S) $2000
More inspections at East Coast Wall Coatings, INC.
View East Coast Wall Coatings, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339364150.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.