NEW HAVEN, CT ·
OSHA Inspection: RAMIREZ CONTRACTOR LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RAMIREZ CONTRACTOR LLC in 66 VISTA STREET, NEW HAVEN, CT 06515 (NAICS 238160). OSHA activity number 339366718.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RAMIREZ CONTRACTOR LLC
- Site address
- 66 VISTA STREET
- City
- NEW HAVEN
- State
- CT
- ZIP
- 06515
- Mailing
- 276 MOUNTAIN GROVE STREET, BRIDGEPORT, CT 06605
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 2
- Ownership type
- Private (A)
Citations
8 citations on file for this inspection.
1926.451 B02 I
- Issued
- Nov 22, 2013
- Abate by
- Dec 5, 2013
- Penalty
- Initial $1,760 · Current $1,100 Reduced
General-duty citation text
29 CFR 1926.451(b)(2)(i): Each ladder jack scaffold, top plate bracket scaffold, roof bracket scaffold, and pump jack scaffold was not at least 12 inches (30 cm) wide:(a)(LOCATION)(IDENTIFY SPECIFIC OPERATIONS AND/OR CONDITIONS)(DESCRIBE HAZARDS WHERE NECESSARY) JOBSITE: The platform of the ladderjack scaffold was less that 12 inches wide.
Recent events (2)
- · I (S) $1100
- · Z (S) $1760
1926.451 F07
- Issued
- Nov 22, 2013
- Abate by
- Dec 19, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. JOBSITE: The ladderjack scaffold from which employees were using as a means of access to the roof of a residential house was not erected under the supervision and direction of a competent person.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.451 G01 I
- Issued
- Nov 22, 2013
- Abate by
- Dec 5, 2013
- Penalty
- Initial $2,200 · Current $1,300 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: JOBSITE: The employees installing copper flashing and roof shingles were exposed to the hazard of falling 16 ft 5 inches to the ground while working/walking on a ladderjack scaffold platform without the use of a personal fall arrest system.
Recent events (2)
- · I (S) $1300
- · Z (S) $2200
1926.452 K02
- Issued
- Nov 22, 2013
- Abate by
- Dec 5, 2013
- Penalty
- Initial $2,200 · Current $1,300 Reduced
General-duty citation text
29 CFR 1926.452(k)(2): Ladders used to support ladder jack scaffolding did not meet the requirements of subpart X of this part -- Stairways and Ladders: JOBSITE: The horizontal distance to the vertical support to the base of the Werner 20 ft aluminum extension ladder used as a support ladder of the ladderjack scaffold used by employees was greater than one fourth (1/4) the working length of the ladder.
Recent events (2)
- · I (S) $1300
- · Z (S) $2200
1926.454 A
- Issued
- Nov 22, 2013
- Abate by
- Dec 19, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. JOBSITE: The employees performing roofing work from the platform of a ladderjack scaffold had not received training and information with ladder jack scaffolds.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.451 F06
- Issued
- Nov 22, 2013
- Abate by
- Dec 5, 2013
- Penalty
- Initial $4,400 · Current $3,000 Reduced
General-duty citation text
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).Note: Specify distances as indicated in table in paragraph (f)(6) of this section. JOBSITE: The employees installing copper flashing and roof shingles were exposed to the hazard of severe electrical shock while working/walking on a ladderjack scaffold platform that was in close proximity to overhear powerlines to the house. Ramirez Contractor, LLC was previously cited for a violation of this occupational safety and health standard {29 CFR 1926.451(f)(6)}, which was contained in OSHA inspection number 898454, citation number 01, item number 001a and was affirmed as a final order on 07/12/2013, with respect to a workplace located at 264 Wade Street, Bridgeport, CT 06604.
Recent events (2)
- · I (R) $3000
- · Z (R) $4400
1926.501 B11
- Issued
- Nov 22, 2013
- Abate by
- Dec 5, 2013
- Penalty
- Initial $6,160 · Current $4,300 Reduced
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: JOBSITE: The employee installing copper flashing around a chimney of a steep (12 in 12 pitched) roof was not protected from falling 16 ft 5 inches to the ground with guardrails, safety net, fall arrest system or other equivalent means. Ramirez Contractor, LLC was previously cited for a violation of this occupational safety and health standard {29 CFR 1926.501(b)(11)}, which was contained in OSHA inspection number 109178103, citation number 01, item number 001 and was affirmed as a final order on 02/07/2011, with respect to a workplace located at 540 Ogden Street, Bridgeport, CT 06608.
Recent events (2)
- · I (R) $4300
- · Z (R) $6160
1926.503 A01
- Issued
- Nov 22, 2013
- Abate by
- Dec 19, 2013
- Penalty
- Initial $4,400 · Current $3,000 Reduced
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: JOBSITE: The employee installing copper flashing around a chimney of a steep (12 in 12 pitched) roof and exposed to the hazard of falling was not provided with training and recognition of hazards associated with falls or the procedures necessary to eliminate or minimize such hazards. Ramirez Contractor, LLC was previously cited for a violation of this occupational safety and health standard {29 CFR 1926.503(a)(1)}, which was contained in OSHA inspection number 109178103, citation number 01, item number 003a, issued on 01/21/2011 and was affirmed as a final order on 02/07/2011, with respect to a workplace located at 540 Ogden Street, Bridgeport, CT 06608.
Recent events (2)
- · I (R) $3000
- · Z (R) $4400
More inspections at Ramirez Contractor LLC
View Ramirez Contractor LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339366718.