Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TCH DIRECTIONAL DRILLING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TCH DIRECTIONAL DRILLING in NADINE ST. AT MAINT ST., HOUSTON, TX 77008 (NAICS 238910). OSHA activity number 339389694.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch TCH Directional Drilling — free Get an email when a new federal OSHA severe-injury report for TCH Directional Drilling is published. One employer, no account, unsubscribe in one click.
Site address
NADINE ST. AT MAINT ST.
City
HOUSTON
State
TX
ZIP
77008
Mailing
4105 FM 2351, FRIENDSWOOD, TX 77546
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
45
Ownership type
A

3 citations on file for this inspection.

1926.651 C02

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 17, 2013
Abate by
Sep 23, 2013
Penalty
Initial $2,100 · Current $1,260 Reduced
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:   The employer does not provide a stairway, ladder, ramp or other safe means of egress in trench excavations that are 4 feet or more in depth.  This violation was observed on or about September 4, 2013, at the excavation site where an employee was exposed to a fall hazard when entering and exiting an excavation, from an area 4.5 feet in depth, without a safe means of egress.     Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that employees are provided a safe means of egress when working in excavations that are 4 feet or more in depth.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2100

1926.651 J02

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 17, 2013
Abate by
Sep 23, 2013
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.    The employer does not keep excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations at least 2 feet from the edge of the excavation.  This violation was observed on or about September 4, 2013, at the excavation site where an employee was exposed to a struck-by hazard when working in an excavation with the spoil pile at the edge of the excavation.     Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that employees are protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into the excavation.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1926.652 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 17, 2013
Abate by
Sep 23, 2013
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c). The employer had not complied with the provisions of 29 CFR 1926.652(b)(1)(i):    The employer does not each employee working in excavations from cave-ins by an adequate protective system.  This violation was observed on or about September 4, 2013, at the excavation site where an employee was exposed to struck-by and crushed-by hazards when working in an excavation that was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section     Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that employees are protected from cave-ins by an adequate protective system.
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900

View TCH Directional Drilling's full OSHA safety record →