Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MILLER CONSTRUCTION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MILLER CONSTRUCTION in 280 EASTON ROAD, WARRINGTON, PA 18976 (NAICS 238140). OSHA activity number 339391492.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Miller Construction — free Get an email when a new federal OSHA severe-injury report for Miller Construction is published. One employer, no account, unsubscribe in one click.
Establishment
MILLER CONSTRUCTION
Site address
280 EASTON ROAD
City
WARRINGTON
State
PA
ZIP
18976
Mailing
1609 MAKEFIELD ROAD, YARDLEY, PA 19067
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 25, 2013
Penalty
Initial $1,600 · Current $1,200 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii):  a)  Rear Of Building - employees are using a tubular welded frame scaffold that was not fully planked between the uprights on the working level, on or about 8/28/13.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1600

1926.451 G01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:  a)  Rear Of Building - employees are working from a tubular welded frame scaffold, 12 feet above grade, without any means of fall protection to protect them from falling to the lower level.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Miller Construction's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339391492.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.