Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GENERAL ELECTRIC INTERNATIONAL, INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of GENERAL ELECTRIC INTERNATIONAL, INC. in 24 PORTLAND STREET, OLD TOWN, ME 04468 (NAICS 221118). OSHA activity number 339406134.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch General Electric International, INC. — free Get an email when a new federal OSHA severe-injury report for General Electric International, INC. is published. One employer, no account, unsubscribe in one click.
Site address
24 PORTLAND STREET
City
OLD TOWN
State
ME
ZIP
04468
Mailing
244 BAYVIEW STREET, YARMOUTH, ME 04096
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221118
Employees
1
Ownership type
A

3 citations on file for this inspection.

1910.219 C02 I

Other-than-serious 1 instance 1 exposed
Issued
Sep 30, 2013
Penalty
Initial $2,250 · Current $1,350 Reduced
29 CFR 1910.219(c)(2)(i): All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, shall be protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires.     #4 Turbine - On or about June 25, 2013, exposed parts of the exciter shaft less than seven feet from the floor were not protected by a stationary casing enclosing shaft completely or by a trough.
Recent events (3)
  • — F (O) $1350
  • — C (S) $2250
  • — Z (S) $2250

1910.219 C04 I

Other-than-serious 1 instance 1 exposed
Issued
Sep 30, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.219(c)(4)(i): Unguarded shaft end(s) projected more than one half the diameter of the shaft:     #4 Turbine - On or about June 25, 2013, the unguarded shaft end of the exciter projected more than one half the diameter of the shaft.
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1910.269 P04 III

Other-than-serious 1 instance 1 exposed
Issued
Sep 30, 2013
Penalty
Initial $3,750 · Current $2,250 Reduced
29 CFR 1910.269(p)(4)(iii): If, during operation of the mechanical equipment, the equipment could become energized, the operation shall also comply with at least one of paragraphs (p)(4)(iii)(A) through (p)(4)(iii)(C) of this section.     #4 Turbine - On or about June 25, 2013, at least one of paragraphs (p)(4)(iii)(A) through (p)(4)(iii) (C) of this section was not complied with, when the 30 ton overhead crane was used to move a metal guard into position above the 100-250 volt exciter.
Recent events (3)
  • — F (O) $2250
  • — C (S) $3750
  • — Z (S) $3750

View General Electric International, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339406134.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.