OSHA Inspection: AMS VANS, INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AMS VANS, INC in 5555 OAKBROOK PARKWAY #580, NORCROSS, GA 30093 (NAICS 441229). OSHA activity number 339410706.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AMS Vans, INC for free Get an email when a new federal OSHA severe-injury report for AMS Vans, INC is published. One employer, no account, unsubscribe in one click.
Establishment
AMS VANS, INC
Site address
5555 OAKBROOK PARKWAY #580
City
NORCROSS
State
GA
ZIP
30093
Mailing
6275 LAWRENCEVILLE HIGHWAY, TUCKER, GA 30084
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441229
Employees
37
Ownership type
A

18 citations on file for this inspection.

1910.36 D01

Serious Gravity 10 1 instance 5 exposed
Issued
Jan 17, 2014
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:  On or about 9/12/2013 at 5555 Oakbrook Parkway, Suite 580, Norcross, GA: employees working in the garage area were exposed to smoke inhalation and burn hazards where the emergency exit door was locked with no key available.
Recent events (2)
  • · I (S) $2940
  • · Z (S) $4900

1910.37 A04

Serious Gravity 5 2 instances 37 exposed
Issued
Jan 17, 2014
Penalty
Initial $2,975 · Current $1,785 Reduced
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency were not in proper working order at all times:  A. On or about 9/12/2013 at 5555 Oakbrook Parkway, Suite 580, Norcross, GA: employees working in the garage area were exposed to smoke inhalation and burn hazards where the emergency exit light to exit through Josh's office was inoperative.  B. On or about 9/12/2013 at 5555 Oakbrook Parkway, Suite 500, Norcross, GA: employees working in the showroom area were exposed to smoke inhalation and burn hazards where the emergency exit light to exit the showroom was inoperative.
Recent events (2)
  • · I (S) $1785
  • · Z (S) $2975

1910.101 B

Serious Gravity 5 1 instance 15 exposed
Issued
Jan 17, 2014
Penalty
Initial $2,975 · Current $1,785 Reduced
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:  A. On or about 9/12/2013 at 5555 Oakbrook Parkway, Suite 580, Norcross, GA: employees were exposed to potential struck-by hazards where the empty Argon cylinder was not secured.   B. On or about 9/12/2013 at 5555 Oakbrook Parkway, Suite 580, Norcross, GA: employees were exposed to potential struck-by hazards where the empty Argon cylinder cap was not installed.
Recent events (2)
  • · I (S) $1785
  • · Z (S) $2975

1910.157 E02

Serious Gravity 1 1 instance 37 exposed
Issued
Jan 17, 2014
Penalty
Initial $1,785 · Current $1,071 Reduced
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  On or about 9/12/2013 at 5555 Oakbrook Parkway, Suite 580, Norcross, GA: employees required to fight incipient level fire were exposed to smoke inhalation and burn hazards where the fire extinguishers were not inspected since 12/12/2012. One extinguisher was discovered to be overcharged.
Recent events (2)
  • · I (S) $1071
  • · Z (S) $1785

1910.157 G01

Serious Gravity 1 1 instance 37 exposed
Issued
Jan 17, 2014
Abate by
Mar 7, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage firefighting:  On or about 9/12/2013 at 5555 Oakbrook Parkway, Suite 580, Norcross, GA: employees are exposed to smoke inhalation and burn hazards where they are expected to fight incipient level fires and are not trained to do so.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.178 L01 I

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 17, 2014
Abate by
Mar 7, 2014
Penalty
Initial $2,100 · Current $1,260 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  On or about 9/12/2013 at 5555 Oakbrook Parkway, Suite 580, Norcross, GA: an employee that operates the powered industrial truck was not trained.
Recent events (2)
  • · I (S) $1260
  • · Z (S) $2100

1910.178 L06

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 17, 2014
Abate by
Mar 7, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):  On or about 9/12/2013 at 5555 Oakbrook Parkway, Suite 580, Norcross, GA: the employer did not have a certification of employees trained to operate powered industrial trucks.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.178 Q07

Serious Gravity 1 1 instance 15 exposed
Issued
Jan 17, 2014
Abate by
Mar 7, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service:  On or about 9/12/2013 at 5555 Oakbrook Parkway, Suite 580, Norcross, GA: employees do not perform daily inspections of the powered industrial truck.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.215 A01

Serious Gravity 10 2 instances 1 exposed
Issued
Jan 17, 2014
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1910.215(a)(1): Abrasive wheel(s) used on grinding machinery were not used with safety guard(s):  On or about 9/12/2013 at 5555 Oakbrook Parkway, Suite 580, Norcross, GA: employees were exposed to amputation hazards where the:  A. Makita 4 1/2" hand grinder did not have the guard installed; and B. Makita 4" hand grinder did not have the guard installed.
Recent events (2)
  • · I (S) $2940
  • · Z (S) $4900

1910.215 A04

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 17, 2014
Penalty
Initial $2,975 · Current $1,785 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  On or about 9/12/2013 at 5555 Oakbrook Parkway, Suite 580, Norcross, GA: Employees performing grinding operations were exposed to struck-by hazards where the work rest was not installed on the grinder exposing a one half inch gap between the grinding wheel and the frame.
Recent events (2)
  • · I (S) $1785
  • · Z (S) $2975

1910.242 B

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 17, 2014
Penalty
Initial $2,975 · Current $1,785 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  On or about 9/12/2013 at 5555 Oakbrook Parkway, Suite 580, Norcross, GA: Employees performing cleaning operations with compressed air were exposed to struck-by hazards where the compressed air was measured at 78 PSI.
Recent events (2)
  • · I (S) $1785
  • · Z (S) $2975

1910.303 B01

Serious Gravity 5 1 instance 15 exposed
Issued
Jan 17, 2014
Penalty
Initial $3,570 · Current $2,419 Reduced
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:  On or about 9/12/2013 at 5555 Oakbrook Parkway, Suite 580, Norcross, GA: Employees working in the garage bay were exposed to electrical hazards where an exposed, hot 120 V electrical wire was hanging from the ceiling 34" above the floor.
Recent events (2)
  • · I (S) $2419
  • · Z (S) $3570

1910.303 B02

Serious Gravity 5 1 instance 15 exposed
Issued
Jan 17, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  On or about 9/12/2013 at 5555 Oakbrook Parkway, Suite 580, Norcross, GA: Employees working in the garage bay were exposed to electrical hazards where a 120 V metallic electrical quad box was hanging from the ceiling 34" above the floor being used to power a 32" fan and drop light .
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.303 F02

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 17, 2014
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  On or about 9/12/2013 at 5555 Oakbrook Parkway, Suite 580, Norcross, GA: employees were exposed to electrical hazards where the 208 electrical panel was not marked to identify what each switch operated.
Recent events (2)
  • · I (S) $2100
  • · Z (S) $3500

1910.305 B01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 17, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  A.    On or about 9/12/2013 at 5555 Oakbrook Parkway, Suite 580, Norcross, GA: an employee that is expected to operate the 208 V electrical panel in the paint bay is potentially exposed to electrical hazards where the panel was missing blanks, exposing the electrical components inside.  B.    On or about 9/12/2013 at 5555 Oakbrook Parkway, Suite 580, Norcross, GA: employees were exposed to potential electrical hazards where the 208 V electrical panel had unused openings in the panel that did not cover the live parts inside.  C.    On or about 9/12/2013 at 5555 Oakbrook Parkway, Suite 580, Norcross, GA: employees were exposed to electrical hazards where the 208 V electrical box was missing knockouts in the paint bay.  D.    On or about 9/12/2013 at 5555 Oakbrook Parkway, Suite 580, Norcross, GA: employees were exposed to electrical hazards where the 120 V metallic electrical box was missing knockouts at the tire storage area.  E.    On or about 9/12/2013 at 5555 Oakbrook Parkway, Suite 580, Norcross, GA: employees were exposed to electrical hazards where the 120 V fluorescent lights in the paint area were missing knockouts.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.304 G05

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 17, 2014
Penalty
Initial $2,975 · Current $1,785 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:   On or about 9/12/2013 at 5555 Oakbrook Parkway, Suite 580, Norcross, GA: an employee was exposed to shock hazards where a 120 V, 32" floor fan was missing the grounding pin.
Recent events (2)
  • · I (S) $1785
  • · Z (S) $2975

1910.305 B02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 17, 2014
Penalty
Initial $2,975 · Current $1,785 Reduced
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  On or about 9/12/2013 at 5555 Oakbrook Parkway, Suite 580, Norcross, GA: employees were exposed to electrical hazards where the two 120 V metallic electrical boxes were missing faceplates at the workstation next to the electrical box in the paint bay, the 120 V metallic electrical box at the tire storage area in the paint bay.
Recent events (2)
  • · I (S) $1785
  • · Z (S) $2975

1910.39 B

Other-than-serious 1 instance 37 exposed
Issued
Jan 17, 2014
Abate by
Mar 7, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.39(b): A fire prevention was not in writing, kept in the workplace, and made available to employees for review:  On or about 9/12/2013 at 5555 Oakbrook Parkway, Suite 580, Norcross, GA: the employer failed to provide a fire prevention program where employees are required to fight incipient level fires.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View AMS Vans, INC's full OSHA safety record →