Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: J & J PALLET SOLUTIONS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of J & J PALLET SOLUTIONS, INC. in 4099 OLD DIXIE HWY SUITE #100, HAPEVILLE, GA 30354 (NAICS 321920). OSHA activity number 339413502.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J & J Pallet Solutions, INC. for free Get an email when a new federal OSHA severe-injury report for J & J Pallet Solutions, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4099 OLD DIXIE HWY SUITE #100
City
HAPEVILLE
State
GA
ZIP
30354
Mailing
4099 OLD DIXIE HWY SUITE #100, HAPEVILLE, GA 30354
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
64
Ownership type
Private (A)

11 citations on file for this inspection.

1910.110 E04 III

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 11, 2014
Penalty
Initial $2,529 · Current $1,264 Reduced
29 CFR 1910.110(e)(4)(iii): Permanent and removable fuel containers were not securely mounted to prevent jarring loose, slipping, or rotating:     (a) Outside receiving area, a Toyota propane-powered forklift was being operated with a propane fuel cylinder that was not securely mounted.  The cylinder mounting clamp was missing, exposing the employees to a fire and explosion hazard.
Recent events (2)
  • · I (S) $1264
  • · Z (S) $2529

1910.147 C04 II B

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 11, 2014
Abate by
Apr 2, 2014
Penalty
Initial $2,975 · Current $1,488 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:     (a) Throughout the production area, adequate specific procedures for shutting down, isolating, and securing energy sources were not developed and utilized when servicing and maintaining equipment such as, but not limited to, pallet stackers, teardown saws and air compressors. The employees were exposed to electrical and amputation hazards.
Recent events (2)
  • · I (S) $1487.5
  • · Z (S) $2975

1910.219 F03

Serious Gravity 5 2 instances 7 exposed
Issued
Mar 11, 2014
Abate by
Apr 2, 2014
Penalty
Initial $2,975 · Current $1,488 Reduced
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed:    (a) Red pallet area, the chain conveyers for the pallet stackers #1, #2, and #3 had unguarded chains and sprockets, exposing the employees to an amputation hazard.    (b) White pallet area, the chain conveyers for the pallet stackers #1, #2, #3 and #4 had unguarded chains and sprockets, exposing the employees to an amputation hazard.
Recent events (2)
  • · I (S) $1487.5
  • · Z (S) $2975

1910.303 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 11, 2014
Abate by
Apr 2, 2014
Penalty
Initial $2,975 · Current $1,488 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    (a) Red pallet area, on the east wall, the electrical panel, and electrical outlet boxes providing 110 volts AC and 220 volts AC, were not mounted in accordance with manufacturer's instructions, exposing the employees to an electrical hazard.
Recent events (2)
  • · I (S) $1487.5
  • · Z (S) $2975

1910.303 F

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 11, 2014
Abate by
Apr 2, 2014
Penalty
Initial $2,975 · Current $1,488 Reduced
29 CFR 1910.303(f): Each disconnecting means for motors and appliances was not located and arranged so the purpose was evident, nor legibly marked to indicate its purpose:    (a) Red pallet area, on the east wall, the disconnect switches on an electrical panel were not marked to indicate its purpose.
Recent events (2)
  • · I (S) $1487.5
  • · Z (S) $2975

1910.303 G01

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 11, 2014
Abate by
Apr 2, 2014
Penalty
Initial $2,975 · Current $1,488 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:    (a) East side of the warehouse, access to the main electrical panel was restricted by equipment that was stored 24 inches in front of the panel and large electrical cords that were placed on the floor in front of the panel.  Employees were exposed to tripping and fall hazards.
Recent events (2)
  • · I (S) $1487.5
  • · Z (S) $2975

1910.303 G02 I

Serious Gravity 5 2 instances 5 exposed
Issued
Mar 11, 2014
Abate by
Apr 2, 2014
Penalty
Initial $2,975 · Current $1,488 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    (a) Red pallet area, an electrical junction box mounted on the east wall, had live electrical wires carrying 110 volts AC that were not protected from accidental contact. The electrical junction box did not have a cover installed, exposing the employees to an electrical hazard.    (b) East side of the warehouse, an electrical junction box for compressor #2 had live electrical wires carrying 220 volts AC that were not protected from accidental contact. The electrical junction box did not have the cover properly installed, exposing the employees to an electrical hazard.
Recent events (2)
  • · I (S) $1487.5
  • · Z (S) $2975

1910.305 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 11, 2014
Penalty
Initial $2,529 · Current $1,265 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    (a) East side of the warehouse, the main electrical panel had an unused opening that was not effectively covered, exposing the employees to an electrical hazard.
Recent events (2)
  • · I (S) $1264.5
  • · Z (S) $2529

1910.305 G01 IV

Serious Gravity 10 1 instance 64 exposed
Issued
Mar 11, 2014
Abate by
Apr 2, 2014
Penalty
Initial $4,900 · Current $2,451 Reduced
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv):    (a) Throughout the facility, electrical flexible cords were being used as a substitute for the fixed wiring for the pallet stackers, attached to metal beams and other metal structures and concealed behind walls and equipment, exposing the employees to an electrical and fire hazard.
Recent events (2)
  • · I (S) $2450.5
  • · Z (S) $4900

1910.178 A06

Other-than-serious 1 instance 1 exposed
Issued
Mar 11, 2014
Abate by
Apr 2, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates and markings were in place:  (a) Outside receiving area, the nameplate and markings on the Toyota propane-powered forklift were not maintained in legible condition.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.178 L04 I

Other-than-serious 1 instance 9 exposed
Issued
Mar 11, 2014
Abate by
Apr 2, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(4)(i): Refresher training, including an evaluation of the effectiveness of that training, was not conducted as required by paragraph (l)(4)(ii) to ensure that the operator had the knowledge and skills needed to operate the powered industrial truck safely:  (a) Throughout the facility, forklift operators were not provided with refresher training to ensure the operators had the knowledge and skill necessary to operate the forklift safely.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View J & J Pallet Solutions, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339413502.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.