HAPEVILLE, GA ·
OSHA Inspection: J & J PALLET SOLUTIONS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of J & J PALLET SOLUTIONS, INC. in 4099 OLD DIXIE HWY SUITE #100, HAPEVILLE, GA 30354 (NAICS 321920). OSHA activity number 339413502.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J & J PALLET SOLUTIONS, INC.
- Site address
- 4099 OLD DIXIE HWY SUITE #100
- City
- HAPEVILLE
- State
- GA
- ZIP
- 30354
- Mailing
- 4099 OLD DIXIE HWY SUITE #100, HAPEVILLE, GA 30354
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321920
- Employees
- 64
- Ownership type
- Private (A)
Citations
11 citations on file for this inspection.
1910.110 E04 III
- Issued
- Mar 11, 2014
- Penalty
- Initial $2,529 · Current $1,264 Reduced
General-duty citation text
29 CFR 1910.110(e)(4)(iii): Permanent and removable fuel containers were not securely mounted to prevent jarring loose, slipping, or rotating: (a) Outside receiving area, a Toyota propane-powered forklift was being operated with a propane fuel cylinder that was not securely mounted. The cylinder mounting clamp was missing, exposing the employees to a fire and explosion hazard.
Recent events (2)
- · I (S) $1264
- · Z (S) $2529
1910.147 C04 II B
- Issued
- Mar 11, 2014
- Abate by
- Apr 2, 2014
- Penalty
- Initial $2,975 · Current $1,488 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: (a) Throughout the production area, adequate specific procedures for shutting down, isolating, and securing energy sources were not developed and utilized when servicing and maintaining equipment such as, but not limited to, pallet stackers, teardown saws and air compressors. The employees were exposed to electrical and amputation hazards.
Recent events (2)
- · I (S) $1487.5
- · Z (S) $2975
1910.219 F03
- Issued
- Mar 11, 2014
- Abate by
- Apr 2, 2014
- Penalty
- Initial $2,975 · Current $1,488 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed: (a) Red pallet area, the chain conveyers for the pallet stackers #1, #2, and #3 had unguarded chains and sprockets, exposing the employees to an amputation hazard. (b) White pallet area, the chain conveyers for the pallet stackers #1, #2, #3 and #4 had unguarded chains and sprockets, exposing the employees to an amputation hazard.
Recent events (2)
- · I (S) $1487.5
- · Z (S) $2975
1910.303 B02
- Issued
- Mar 11, 2014
- Abate by
- Apr 2, 2014
- Penalty
- Initial $2,975 · Current $1,488 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) Red pallet area, on the east wall, the electrical panel, and electrical outlet boxes providing 110 volts AC and 220 volts AC, were not mounted in accordance with manufacturer's instructions, exposing the employees to an electrical hazard.
Recent events (2)
- · I (S) $1487.5
- · Z (S) $2975
1910.303 F
- Issued
- Mar 11, 2014
- Abate by
- Apr 2, 2014
- Penalty
- Initial $2,975 · Current $1,488 Reduced
General-duty citation text
29 CFR 1910.303(f): Each disconnecting means for motors and appliances was not located and arranged so the purpose was evident, nor legibly marked to indicate its purpose: (a) Red pallet area, on the east wall, the disconnect switches on an electrical panel were not marked to indicate its purpose.
Recent events (2)
- · I (S) $1487.5
- · Z (S) $2975
1910.303 G01
- Issued
- Mar 11, 2014
- Abate by
- Apr 2, 2014
- Penalty
- Initial $2,975 · Current $1,488 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: (a) East side of the warehouse, access to the main electrical panel was restricted by equipment that was stored 24 inches in front of the panel and large electrical cords that were placed on the floor in front of the panel. Employees were exposed to tripping and fall hazards.
Recent events (2)
- · I (S) $1487.5
- · Z (S) $2975
1910.303 G02 I
- Issued
- Mar 11, 2014
- Abate by
- Apr 2, 2014
- Penalty
- Initial $2,975 · Current $1,488 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): (a) Red pallet area, an electrical junction box mounted on the east wall, had live electrical wires carrying 110 volts AC that were not protected from accidental contact. The electrical junction box did not have a cover installed, exposing the employees to an electrical hazard. (b) East side of the warehouse, an electrical junction box for compressor #2 had live electrical wires carrying 220 volts AC that were not protected from accidental contact. The electrical junction box did not have the cover properly installed, exposing the employees to an electrical hazard.
Recent events (2)
- · I (S) $1487.5
- · Z (S) $2975
1910.305 B01 II
- Issued
- Mar 11, 2014
- Penalty
- Initial $2,529 · Current $1,265 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) East side of the warehouse, the main electrical panel had an unused opening that was not effectively covered, exposing the employees to an electrical hazard.
Recent events (2)
- · I (S) $1264.5
- · Z (S) $2529
1910.305 G01 IV
- Issued
- Mar 11, 2014
- Abate by
- Apr 2, 2014
- Penalty
- Initial $4,900 · Current $2,451 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv): (a) Throughout the facility, electrical flexible cords were being used as a substitute for the fixed wiring for the pallet stackers, attached to metal beams and other metal structures and concealed behind walls and equipment, exposing the employees to an electrical and fire hazard.
Recent events (2)
- · I (S) $2450.5
- · Z (S) $4900
1910.178 A06
- Issued
- Mar 11, 2014
- Abate by
- Apr 2, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates and markings were in place: (a) Outside receiving area, the nameplate and markings on the Toyota propane-powered forklift were not maintained in legible condition.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.178 L04 I
- Issued
- Mar 11, 2014
- Abate by
- Apr 2, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(i): Refresher training, including an evaluation of the effectiveness of that training, was not conducted as required by paragraph (l)(4)(ii) to ensure that the operator had the knowledge and skills needed to operate the powered industrial truck safely: (a) Throughout the facility, forklift operators were not provided with refresher training to ensure the operators had the knowledge and skill necessary to operate the forklift safely.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at J & J Pallet Solutions, INC.
View J & J Pallet Solutions, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321920)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339413502.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.