CANASTOTA, NY —
OSHA Inspection: CANASTOTA N/C CORP.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CANASTOTA N/C CORP. in 121 WEST CENTER STREET, CANASTOTA, NY 13032 (NAICS 332710). OSHA activity number 339415739.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CANASTOTA N/C CORP.
- Site address
- 121 WEST CENTER STREET
- City
- CANASTOTA
- State
- NY
- ZIP
- 13032
- Mailing
- 121 WEST CENTER STREET, CANASTOTA, NY 13032
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 19
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.212 A01
- Issued
- Oct 11, 2013
- Abate by
- Nov 16, 2013
- Penalty
- Initial $2,800 · Current $1,960 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts and ingoing nip points: a) Manual End, on or about 9/17/13: Rotating chuck on a Beaver milling machine was not guarded. b) Mill Room, on or about 9/17/13: Rotating chucks on a Delta Rockwell drill press and an Ironsmith drill press were not guarded. c) Mill Room, on or about 9/17/13: Rotating nut projections on a Craftsman buffing wheel next to Mazak #1 and on a Craftsman buffing wheel next to Mazak #2 were not guarded. d) Mill Room, on or about 9/17/13: Rotating nut projections on a Harbor Freight buffing wheel next to the Mazak 250 North, were not guarded. e) 5000 Room, on or about 9/17/13: Rotating chuck on a K&F drill press was not guarded. f) 5000 Room, on or about 9/17/13: Rotating nut projections on a Dayton buffing wheel was not guarded on the left side. g) 5000 Room, on or about 9/17/13: Ingoing nip points on the chip conveyor for the Mazak QT Nexus 200 MS were not guarded at the discharge chute. h) Mill/Lathe Room, on or about 9/17/13: Ingoing nip points on the chip conveyor for the Mazak QT20 were not guarded at the discharge chute. Abatement documentation must be submitted for these items.
Recent events (2)
- — I (S) $1960
- — Z (S) $2800
1910.212 B
- Issued
- Oct 11, 2013
- Abate by
- Nov 16, 2013
- Penalty
- Initial $1,020 · Current $714 Reduced
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a) Mill Room, on or about 9/17/13: An Ironsmith drill press was not secured to prevent walking or moving. b) 5000 Room, on or about 9/17/13: A K & F drill press was not secured to prevent walking or moving. Abatement certification must be submitted for these items.
Recent events (2)
- — I (S) $714
- — Z (S) $1020
1910.178 L04 III
- Issued
- Oct 11, 2013
- Abate by
- Nov 16, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) At the establishment, on or about 9/17/13: Evaluations of each powered industrial truck operator's performance had not been conducted for all operators once every three years. Abatement certification must be submitted for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Oct 11, 2013
- Abate by
- Nov 16, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Manual End, on or about 9/17/13: A strip outlet providing current to two power feeds, a light and a digital readout, was attached to a Beaver milling machine and being used as permanent wiring. Abatement certification must be submitted for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Canastota N/C Corp.
View Canastota N/C Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 332710)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339415739.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.