Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CANASTOTA N/C CORP.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CANASTOTA N/C CORP. in 121 WEST CENTER STREET, CANASTOTA, NY 13032 (NAICS 332710). OSHA activity number 342709755.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Canastota N/C Corp. — free Get an email when a new federal OSHA severe-injury report for Canastota N/C Corp. is published. One employer, no account, unsubscribe in one click.
Establishment
CANASTOTA N/C CORP.
Site address
121 WEST CENTER STREET
City
CANASTOTA
State
NY
ZIP
13032
Mailing
121 WEST CENTER STREET, CANASTOTA, NY 13032
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
25
Ownership type
A

2 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 3 instances 3 exposed
Issued
Nov 6, 2017
Penalty
Initial $3,694 · Current $2,771 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, pinch points, moving parts, flying chips and sparks:  a)  Mill Room 2, on or about 10/18/17:  Pinch points and moving parts on the tool changer carousel for the Mazak PFH 4800, Mazak HCN 5000 #1 and Mazak HCN 5000 #2 milling machines were not guarded.
Recent events (2)
  • — I (S) $2770.5
  • — Z (S) $3694

1910.37 A04

Other-than-serious 2 instances 10 exposed
Issued
Nov 6, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times:  a)  Mill Room 1, on or about 10/18/17:  Emergency lighting over the exit door was not working.  b)  Saw Room, on or about 10/18/17:  Emergency lighting over the exit door was not working.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Canastota N/C Corp.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342709755.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.